RECTY |
Record type for batch input of task lists |
RECTY |
|
CHAR |
|
2 |
0 |
|
PLNTY |
Task List Type |
PLNTY |
|
CHAR |
|
1 |
0 |
|
PLNNR |
Key for Task List Group |
PLNNR |
|
CHAR |
|
8 |
0 |
|
PLNAL |
Group Counter |
PLNAL |
|
CHAR |
|
2 |
0 |
|
PLNFL |
Sequence |
PLNFOLGE |
|
CHAR |
|
6 |
0 |
|
VORNR |
Operation/Activity Number |
VORNR |
|
CHAR |
|
4 |
0 |
|
MERKNR |
Inspection Characteristic Number (Batch Input) |
QMERKNR_C |
|
CHAR |
|
4 |
0 |
|
KURZTEXT |
Short Text |
QKURZTEXT |
|
CHAR |
|
40 |
0 |
|
TXTSP |
Language key (batch input) |
SPRAS_BI |
|
CHAR |
|
1 |
0 |
|
VSTEUERKZ |
Key Containing Preset Characteristic Control Indicators |
QSTEUERKZ |
|
CHAR |
|
4 |
0 |
|
TOLERANZSL |
Tolerance Key |
QTOLERANZ |
|
CHAR |
|
4 |
0 |
|
QUANTITAT |
Quantitative Characteristic |
QKZQUNMK |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
MESSWERTE |
Measured Values Must Be Recorded |
QKZQUMK |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
PRUEFKAT |
Reference to Characteristic Attribute Required |
QKZPKAT |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
TOLEROBEN |
Upper Specification Limit |
QKZTOLOB |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
TOLERUNTEN |
Lower Specification Limit |
QKZTOLUN |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
SOLLPRUEF |
Check Target Value |
QKZSOLLPR |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
PUMFKZ |
Inspection Scope |
QPUMFKZ |
|
CHAR |
|
1 |
0 |
Possible values
= |
Fixed inspection scope |
NULL |
Scope not fixed |
< |
Smaller inspection scope allowed |
> |
Larger inspection scope allowed |
|
LZEITKZ |
Long-Term Inspection |
QLZEITKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
ESTUKZ |
Recording Type |
QESTUKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Summarized recording |
+ |
Single-value recording |
* |
Classed recording |
- |
No results recording |
|
DOKUKZ |
Documentation Required for Inspection Results |
QDOKUKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Text documentation of test values is not required |
. |
The test values with valuation R (reject) must be documented |
+ |
All test values must be documented with text |
|
RZWANG |
Characteristic Category |
QRZWANG |
|
CHAR |
|
1 |
0 |
Possible values
X |
Required characteristic |
NULL |
Optional characteristic |
+ |
Required when previous required characteristic is accepted |
- |
Required when previous required characteristic is rejected |
|
SYNCRO |
Synchronization is Active |
QSYNCRO |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
ADDPRO |
Sample Quantity Is Added |
QADDPRO |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
ZERSTPRF |
Destructive Inspection |
QKZDESTROY |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
FORMELMK |
Calculated Characteristic |
QKZFORMEL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
No Formula |
1 |
Input Processing |
X |
Calculated Characteristic |
|
STICHPR |
Sampling Procedure is Required |
QSTICHPR |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
AUSSLOS |
Characteristic Relevant for Qual. Score and Scrap Share |
QAUSSLOS |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
FIXIERT |
Default Control Indicators Cannot Be Changed |
QNAENDKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
BEWFHLZHL |
Recording the Number of Defects |
QBFHLZHL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
LSTKZ |
Control Characteristics Results - QM Subsystem |
QLEITSTKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
VORGAEND |
Specifications Can Be Changed |
QVORGAEND |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
PMMZWANG |
Assignment of Test Equipment Required |
QPMZWANG |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
FEHLREC |
Defects Recording Automatically Called Up |
QFEHLREC |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
AENDBELEG |
Create Change Documents During Results Recording |
QKZAENBEL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
QSPCMK |
SPC Characteristic |
QSPCMK |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
KEINDRUCK |
Print |
QDRUCK1 |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Print |
X |
Do not print |
* |
Do not print at skip |
|
PARA |
Control Indicator "Parameter Characteristic" Set/Not Set |
QPARA |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
PROCESSMK |
Process Characteristic |
QKZPROCCHAR |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
VERWMERKM |
Master Inspection Characteristics |
QMERKNR |
|
CHAR |
|
8 |
0 |
|
QPMK_REF |
Reference to Master Insp. Characteristic in Task List |
QKZ_REF |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
QPMK_ZAEHL |
Plant for the Master Inspection Characteristic |
QZAEHLER |
|
CHAR |
|
4 |
0 |
|
MKVERSION |
Version Number of the Master Inspection Characteristic |
QVERSNRMK |
|
CHAR |
|
6 |
0 |
|
PMETHODE |
Inspection Method |
QPMETHODE |
|
CHAR |
|
8 |
0 |
|
QMTB_WERKS |
Plant |
WERKS_D |
|
CHAR |
|
4 |
0 |
|
PMTVERSION |
Version Number of the Inspection Method |
QVERSNRPM |
|
CHAR |
|
6 |
0 |
|
PROBENR |
Partial Sample for an Insp. Characteristic (Batch Input) |
QPROBEPL_C |
|
CHAR |
|
3 |
0 |
|
PRUEFQUALI |
Inspector Qualification |
QPRQUALIF |
|
CHAR |
|
5 |
0 |
|
MERKGEW |
Weighting of the Characteristic |
QMERKGEW |
|
CHAR |
|
2 |
0 |
|
EEANTVERF |
Fraction Calculation |
QEANTVERF |
|
CHAR |
|
2 |
0 |
|
PSNFH |
Item number of the production resource/tool (batch input) |
PSNFH_BI |
|
CHAR |
|
4 |
0 |
|
DUMMY10 |
Text Line for Additional Information |
QTXT10 |
|
CHAR |
|
10 |
0 |
|
DUMMY20 |
Text Line for Additional Information |
QTXT20 |
|
CHAR |
|
20 |
0 |
|
DUMMY40 |
Text Line for Additional Information |
QTXT40 |
|
CHAR |
|
40 |
0 |
|
STICHPRVER |
Sampling Procedure in Inspection Characteristic |
QSTICHVERF |
|
CHAR |
|
8 |
0 |
|
PROBEMGEH |
Sample Unit of Measure (Batch Input) |
QPROBME_C |
|
CHAR |
|
3 |
0 |
|
PRUEFEINH |
Sample Quantity Factor for Sample (Batch Input) |
QPROBEFAKC |
|
CHAR |
|
6 |
0 |
|
SPCKRIT |
SPC Criterion |
QSPCKRIT |
|
CHAR |
|
3 |
0 |
|
DYNMERKREF |
Tlist Characteristic, Whose Q-Level Is Copied (Batch Input) |
QMERKDYN_C |
|
CHAR |
|
4 |
0 |
|
QDYNREGEL |
Dynamic Modification Rule |
QDYNREGEL |
|
CHAR |
|
3 |
0 |
|
LIEFKZ |
Vendor Considered for Dynamic Modification |
QLIFKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
HERSTKZ |
Manufacturer Considered for Dynamic Modification |
QHERSTKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
KUNDKZ |
Customer Considered for Dynamic Modification |
QKUNDKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
STELLEN |
No. of Decimal Places (Batch Input) |
QSTELLEN_C |
|
CHAR |
|
2 |
0 |
|
MASSEINHSW |
Measurement Unit in Which Quantitative Data Is Maintained |
QMGEH6 |
|
CHAR |
|
6 |
0 |
|
SOLLWERT |
Target Value for a Quantitative Characteristic |
QSOLLWERTC |
|
CHAR |
|
16 |
0 |
|
TOLERANZOB |
Upper Specification Limit |
QTOLOBC |
|
CHAR |
|
16 |
0 |
|
TOLERANZUN |
Lower Specification Limit |
QTOLUNC |
|
CHAR |
|
16 |
0 |
|
KLASANZAHL |
Number of Value Classes for Inspection Results |
QKLASSZAHC |
|
CHAR |
|
3 |
0 |
|
KLASBREITE |
Class Width |
QKLASSBRC |
|
CHAR |
|
16 |
0 |
|
KLASMITTE |
Class Midpoint |
QKLASMITC |
|
CHAR |
|
16 |
0 |
|
GRENZEOB1 |
First Upper Specification Limit |
QGRENZO1C |
|
CHAR |
|
16 |
0 |
|
GRENZEUN1 |
First Lower Specification Limit |
QGRENZU1C |
|
CHAR |
|
16 |
0 |
|
GRENZEOB2 |
Second Upper Specification Limit |
QGRENZO2C |
|
CHAR |
|
16 |
0 |
|
GRENZEUN2 |
Second Lower Specification Limit |
QGRENZU2C |
|
CHAR |
|
16 |
0 |
|
PLAUSIOBEN |
Upper Plausibility Limit |
QPLAUSIOBC |
|
CHAR |
|
16 |
0 |
|
PLAUSIUNTE |
Lower Plausibility Limit |
QPLAUSIUNC |
|
CHAR |
|
16 |
0 |
|
TOLERWEIOB |
Change to Upper Specification Limit |
QTOLWOBC |
|
CHAR |
|
16 |
0 |
|
TOLERWEIUN |
Change to Lower Specification Limit |
QTOLWUNC |
|
CHAR |
|
16 |
0 |
|
TOLERWAB |
Date, from Which the Tolerance Change Is Valid (Batch Input) |
QTOLWAB_C |
|
CHAR |
|
10 |
0 |
|
TOLERWBIS |
Date, to Which the Tolerance Change Is Valid (Batch Input) |
QTOLWBIS_C |
|
CHAR |
|
10 |
0 |
|
FORMELSL |
Check and Calculate Formula in QM |
QFORMELSL |
|
CHAR |
|
1 |
0 |
|
FORMEL1 |
Formula Field |
QFORMEL |
|
CHAR |
|
60 |
0 |
|
FORMEL2 |
Formula Field |
QFORMEL |
|
CHAR |
|
60 |
0 |
|
CODEGRQUAL |
Defect Code Group for General Rejection |
QCODEGRPQL |
|
CHAR |
|
8 |
0 |
|
CODEQUAL |
Defect Code for Rejection: General |
QCODEQL |
|
CHAR |
|
4 |
0 |
|
CODEGR9U |
Defect Code Group for Rejection at Lower Tolerance |
QCODEGRPU |
|
CHAR |
|
8 |
0 |
|
CODE9U |
Defect Code for Rejection at Lower Specification Limit |
QCODEU |
|
CHAR |
|
4 |
0 |
|
CODEGR9O |
Defect Code Group for Rejection at Upper Tolerance |
QCODEGRPO |
|
CHAR |
|
8 |
0 |
|
CODE9O |
Defect Code for Rejection at Upper Specification Limit |
QCODEO |
|
CHAR |
|
4 |
0 |
|
KATAB1 |
Catalog Entry Is a Selected Set |
QKTTAB |
|
CHAR |
|
1 |
0 |
|
KATALGART1 |
Catalog Type of Assigned Code Group or Selected Set |
QKATAUSW |
|
CHAR |
|
1 |
0 |
|
AUSWMENGE1 |
Assigned Code Group or Selected Set |
QCGRAUSW |
|
CHAR |
|
8 |
0 |
|
AUSWMGWRK1 |
Plant of the Assigned Selected Set |
QWERKAUSW |
|
CHAR |
|
4 |
0 |
|
KATAB2 |
Catalog Entry Is a Selected Set |
QKTTAB |
|
CHAR |
|
1 |
0 |
|
KATALGART2 |
Catalog Type of Assigned Code Group or Selected Set |
QKATAUSW |
|
CHAR |
|
1 |
0 |
|
AUSWMENGE2 |
Assigned Code Group or Selected Set |
QCGRAUSW |
|
CHAR |
|
8 |
0 |
|
AUSWMGWRK2 |
Plant of the Assigned Selected Set |
QWERKAUSW |
|
CHAR |
|
4 |
0 |
|
KATAB3 |
Catalog Entry Is a Selected Set |
QKTTAB |
|
CHAR |
|
1 |
0 |
|
KATALGART3 |
Catalog Type of Assigned Code Group or Selected Set |
QKATAUSW |
|
CHAR |
|
1 |
0 |
|
AUSWMENGE3 |
Assigned Code Group or Selected Set |
QCGRAUSW |
|
CHAR |
|
8 |
0 |
|
AUSWMGWRK3 |
Plant of the Assigned Selected Set |
QWERKAUSW |
|
CHAR |
|
4 |
0 |
|
KATAB4 |
Catalog Entry Is a Selected Set |
QKTTAB |
|
CHAR |
|
1 |
0 |
|
KATALGART4 |
Catalog Type of Assigned Code Group or Selected Set |
QKATAUSW |
|
CHAR |
|
1 |
0 |
|
AUSWMENGE4 |
Assigned Code Group or Selected Set |
QCGRAUSW |
|
CHAR |
|
8 |
0 |
|
AUSWMGWRK4 |
Plant of the Assigned Selected Set |
QWERKAUSW |
|
CHAR |
|
4 |
0 |
|
KATAB5 |
Catalog Entry Is a Selected Set |
QKTTAB |
|
CHAR |
|
1 |
0 |
|
KATALGART5 |
Catalog Type of Assigned Code Group or Selected Set |
QKATAUSW |
|
CHAR |
|
1 |
0 |
|
AUSWMENGE5 |
Assigned Code Group or Selected Set |
QCGRAUSW |
|
CHAR |
|
8 |
0 |
|
AUSWMGWRK5 |
Plant of the Assigned Selected Set |
QWERKAUSW |
|
CHAR |
|
4 |
0 |
|
INPPROC |
Parameters for Input Processing in QM Results Recording |
QINPPROC |
|
CHAR |
|
3 |
0 |
|