MANDT |
Client |
MANDT |
|
CLNT |
|
3 |
0 |
|
PLNTY |
Task List Type |
PLNTY |
|
CHAR |
|
1 |
0 |
|
PLNNR |
Key for Task List Group |
PLNNR |
|
CHAR |
|
8 |
0 |
|
PLNKN |
Number of the task list node |
PLNKN |
|
NUMC |
|
8 |
0 |
|
KZEINSTELL |
Characteristic Type |
QKZEINSTMK |
|
CHAR |
|
1 |
0 |
|
MERKNR |
Inspection Characteristic Number |
QMERKNRP |
|
NUMC |
|
4 |
0 |
|
ZAEHL |
Internal counter |
CIM_COUNT |
|
NUMC |
|
8 |
0 |
|
GUELTIGAB |
Valid-From Date |
DATUV |
|
DATS |
|
8 |
0 |
|
SERNV |
Technical status from |
TECHV |
|
CHAR |
|
12 |
0 |
|
LOEKZ |
Deletion Indicator |
LKENZ |
|
CHAR |
|
1 |
0 |
Possible values
|
PARKZ |
Indicator: inactive changes |
PARKZ |
|
CHAR |
|
1 |
0 |
Possible values
|
AENDERGNR |
Change Number |
AENNR |
|
CHAR |
|
12 |
0 |
|
ERSTELLER |
User who created record |
ANNAM |
|
CHAR |
|
12 |
0 |
|
ERSTELLDAT |
Date record created on |
ANDAT |
|
DATS |
|
8 |
0 |
|
AENDERER |
Name of User who Most Recently Changed the Data Record |
QAENDERER |
|
CHAR |
|
12 |
0 |
|
AENDERDAT |
Date on Which Data Record Was Changed |
QDATUMAEND |
|
DATS |
|
8 |
0 |
|
STEUERKZ |
Cntrl Indicator String for Insp. Char./Master Insp. Char. |
QMKCONTROL |
|
CHAR |
|
30 |
0 |
|
QMTB_WERKS |
Plant for Inspection Method |
Q_METH_PLANT |
T001W
|
CHAR |
|
4 |
0 |
|
PMETHODE |
Inspection Method |
QPMETHODE |
QMTB
|
CHAR |
|
8 |
0 |
|
PMTVERSION |
Version Number of the Inspection Method |
QVERSNRPM |
|
CHAR |
|
6 |
0 |
|
QPMK_REF |
Reference to Master Insp. Characteristic in Task List |
QKZ_REF |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
QPMK_ZAEHL |
Plant for the Master Inspection Characteristic |
QZAEHLER |
|
CHAR |
|
4 |
0 |
|
VERWMERKM |
Master Inspection Characteristics |
QMERKNR |
QPMK
|
CHAR |
|
8 |
0 |
|
MKVERSION |
Version Number of the Master Inspection Characteristic |
QVERSNRMK |
|
CHAR |
|
6 |
0 |
|
MKVERSDAT |
Key Date for Version Selection |
QVERSDAT |
|
DATS |
|
8 |
0 |
|
MERKGEW |
Weighting of the Characteristic |
QMERKGEW |
TQ17A
|
CHAR |
|
2 |
0 |
|
PROBENR |
Partial Sample No. for Inspection Charac. in Task List |
QPROBEPL |
|
NUMC |
|
3 |
0 |
|
PRUEFQUALI |
Inspector Qualification |
QPRQUALIF |
TQ11
|
CHAR |
|
5 |
0 |
|
TOLERANZSL |
Tolerance Key |
QTOLERANZ |
TQ29
|
CHAR |
|
4 |
0 |
|
KURZTEXT |
Short Text for Inspection Characteristic |
QTXT_CHA |
|
CHAR |
|
40 |
0 |
|
LTEXTKZ |
Inspection Characteristic Long Text Exists |
QLTEXTKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
LTEXTSPR |
Language Key |
SPRAS |
|
LANG |
|
1 |
0 |
|
LTEXTEKZ |
Physical-Sample-Drawing Text Exists |
QKZPRZIEH |
|
CHAR |
|
1 |
0 |
|
LTXTENTSPR |
Language Key |
SPRAS |
|
LANG |
|
1 |
0 |
|
STELLEN |
Number of Places to the Right of a Decimal Point (Accuracy) |
QSTELLEN |
|
INT1 |
|
3 |
0 |
Possible values
0 |
To a maximum of 10 decimal places |
|
MASSEINHSW |
Unit of Measurement, in Which Quantitative Data Is Stored |
QMASSEH |
T006
|
UNIT |
|
3 |
0 |
|
SOLLWERT |
Target Value for a Quantitative Characteristic |
QSOLLWERTE |
|
FLTP |
|
16 |
16 |
|
SOLLWNI |
Value Not Initial if Set |
QNINITIAL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
TOLERANZOB |
Upper Specification Limit |
QTOLOB |
|
FLTP |
|
16 |
16 |
|
TOLOBNI |
Value Not Initial if Set |
QNINITIAL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
TOLERANZUN |
Lower Tolerance Limit |
QTOLUN |
|
FLTP |
|
16 |
16 |
|
TOLUNNI |
Value Not Initial if Set |
QNINITIAL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
KLASANZAHL |
Number of Value Classes for Inspection Results |
QKLASSZAHL |
|
INT1 |
|
3 |
0 |
|
KLASBREITE |
Class Width |
QKLASSBR |
|
FLTP |
|
16 |
16 |
|
KLASBRNI |
Value Not Initial if Set |
QNINITIAL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
KLASMITTE |
Class Midpoint |
QKLASSMIT |
|
FLTP |
|
16 |
16 |
|
KLASMINI |
Value Not Initial if Set |
QNINITIAL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
GRENZEOB1 |
First Upper Specification Limit |
QGRENZOB1 |
|
FLTP |
|
16 |
16 |
|
GRENZOB1NI |
Value Not Initial if Set |
QNINITIAL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
GRENZEUN1 |
First Lower Specification Limit |
QGRENZUN1 |
|
FLTP |
|
16 |
16 |
|
GRENZUN1NI |
Value Not Initial if Set |
QNINITIAL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
GRENZEOB2 |
Second Upper Specification Limit |
QGRENZOB2 |
|
FLTP |
|
16 |
16 |
|
GRENZOB2NI |
Value Not Initial if Set |
QNINITIAL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
GRENZEUN2 |
Second Lower Specification Limit |
QGRENZUN2 |
|
FLTP |
|
16 |
16 |
|
GRENZUN2NI |
Value Not Initial if Set |
QNINITIAL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
PLAUSIOBEN |
Upper Plausibility Limit |
QPLAUSIOB |
|
FLTP |
|
16 |
16 |
|
PLAUSIOBNI |
Value Not Initial if Set |
QNINITIAL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
PLAUSIUNTE |
Lower Plausibility Limit |
QPLAUSIUN |
|
FLTP |
|
16 |
16 |
|
PLAUSIUNNI |
Value Not Initial if Set |
QNINITIAL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
TOLERWEIOB |
Change to Upper Specification Limit |
QTOLWOB |
|
FLTP |
|
16 |
16 |
|
TOLWOBNI |
Value Not Initial if Set |
QNINITIAL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
TOLERWEIUN |
Change to Lower Specification Limit |
QTOLWUN |
|
FLTP |
|
16 |
16 |
|
TOLWUNNI |
Value Not Initial if Set |
QNINITIAL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
TOLERWAB |
Date from Which the Tolerance Change Is Valid |
QTOLWAB |
|
DATS |
|
8 |
0 |
|
TOLERWBIS |
Date Until Which the Tolerance Change Is Valid |
QTOLWBIS |
|
DATS |
|
8 |
0 |
|
STICHPRVER |
Sampling Procedure in Inspection Characteristic |
QSTICHVERF |
|
CHAR |
|
8 |
0 |
|
FAKPLANME |
Factor for Converting MatUnitOfMeasure to SampUnitOfMeasure |
QUMREN |
|
FLTP |
|
16 |
16 |
|
FAKPROBME |
Factor for Converting SampUnitOfMeasure to MatUnitOfMeasure |
QUMRENPME |
|
FLTP |
|
16 |
16 |
|
PROBEMGEH |
Sample Unit of Measure |
QPROBME |
T006
|
UNIT |
|
3 |
0 |
|
PRUEFEINH |
Sample Quantity Factor for Sample(Mult. Sample Unit of Msr.) |
QPROBEFAK |
|
DEC |
|
5 |
2 |
|
DYNKRIT |
String for Dynamic Modification Criteria (Database Relevant) |
QDYNSTRING |
|
CHAR |
|
10 |
0 |
|
FORMELSL |
Check and Calculate Formula in QM |
QFORMELSL |
|
CHAR |
|
1 |
0 |
|
FORMEL1 |
Formula Field |
QFORMEL |
|
CHAR |
|
60 |
0 |
|
FORMEL2 |
Formula Field |
QFORMEL |
|
CHAR |
|
60 |
0 |
|
CODEGR9U |
Defect Code Group for Rejection at Lower Tolerance |
QCODEGRPU |
|
CHAR |
|
8 |
0 |
|
CODE9U |
Defect Code for Rejection at Lower Specification Limit |
QCODEU |
|
CHAR |
|
4 |
0 |
|
CODEVR9U |
Version Number |
QVERSNR |
|
CHAR |
|
6 |
0 |
|
CODEGR9O |
Defect Code Group for Rejection at Upper Tolerance |
QCODEGRPO |
|
CHAR |
|
8 |
0 |
|
CODE9O |
Defect Code for Rejection at Upper Specification Limit |
QCODEO |
|
CHAR |
|
4 |
0 |
|
CODEVR9O |
Version Number |
QVERSNR |
|
CHAR |
|
6 |
0 |
|
KATAB1 |
Catalog Entry Is a Selected Set |
QKTTAB |
|
CHAR |
|
1 |
0 |
|
KATALGART1 |
Catalog Type of Assigned Code Group or Selected Set |
QKATAUSW |
TQ15
|
CHAR |
|
1 |
0 |
|
AUSWMENGE1 |
Assigned Code Group or Selected Set |
QCGRAUSW |
|
CHAR |
|
8 |
0 |
|
AUSWMGWRK1 |
Plant of the Assigned Selected Set |
QWERKAUSW |
T001W
|
CHAR |
|
4 |
0 |
|
AUSWVERS1 |
Version Number |
QVERSNR |
|
CHAR |
|
6 |
0 |
|
AUSWDAT1 |
Key Date for Version Selection |
QVERSDAT |
|
DATS |
|
8 |
0 |
|
KATAB2 |
Catalog Entry Is a Selected Set |
QKTTAB |
|
CHAR |
|
1 |
0 |
|
KATALGART2 |
Catalog Type of Assigned Code Group or Selected Set |
QKATAUSW |
TQ15
|
CHAR |
|
1 |
0 |
|
AUSWMENGE2 |
Assigned Code Group or Selected Set |
QCGRAUSW |
|
CHAR |
|
8 |
0 |
|
AUSWMGWRK2 |
Plant of the Assigned Selected Set |
QWERKAUSW |
T001W
|
CHAR |
|
4 |
0 |
|
AUSWVERS2 |
Version Number |
QVERSNR |
|
CHAR |
|
6 |
0 |
|
AUSWDAT2 |
Key Date for Version Selection |
QVERSDAT |
|
DATS |
|
8 |
0 |
|
KATAB3 |
Catalog Entry Is a Selected Set |
QKTTAB |
|
CHAR |
|
1 |
0 |
|
KATALGART3 |
Catalog Type of Assigned Code Group or Selected Set |
QKATAUSW |
TQ15
|
CHAR |
|
1 |
0 |
|
AUSWMENGE3 |
Assigned Code Group or Selected Set |
QCGRAUSW |
|
CHAR |
|
8 |
0 |
|
AUSWMGWRK3 |
Plant of the Assigned Selected Set |
QWERKAUSW |
T001W
|
CHAR |
|
4 |
0 |
|
AUSWVERS3 |
Version Number |
QVERSNR |
|
CHAR |
|
6 |
0 |
|
AUSWDAT3 |
Key Date for Version Selection |
QVERSDAT |
|
DATS |
|
8 |
0 |
|
KATAB4 |
Catalog Entry Is a Selected Set |
QKTTAB |
|
CHAR |
|
1 |
0 |
|
KATALGART4 |
Catalog Type of Assigned Code Group or Selected Set |
QKATAUSW |
TQ15
|
CHAR |
|
1 |
0 |
|
AUSWMENGE4 |
Assigned Code Group or Selected Set |
QCGRAUSW |
|
CHAR |
|
8 |
0 |
|
AUSWMGWRK4 |
Plant of the Assigned Selected Set |
QWERKAUSW |
T001W
|
CHAR |
|
4 |
0 |
|
AUSWVERS4 |
Version Number |
QVERSNR |
|
CHAR |
|
6 |
0 |
|
AUSWDAT4 |
Key Date for Version Selection |
QVERSDAT |
|
DATS |
|
8 |
0 |
|
KATAB5 |
Catalog Entry Is a Selected Set |
QKTTAB |
|
CHAR |
|
1 |
0 |
|
KATALGART5 |
Catalog Type of Assigned Code Group or Selected Set |
QKATAUSW |
TQ15
|
CHAR |
|
1 |
0 |
|
AUSWMENGE5 |
Assigned Code Group or Selected Set |
QCGRAUSW |
|
CHAR |
|
8 |
0 |
|
AUSWMGWRK5 |
Plant of the Assigned Selected Set |
QWERKAUSW |
T001W
|
CHAR |
|
4 |
0 |
|
AUSWVERS5 |
Version Number |
QVERSNR |
|
CHAR |
|
6 |
0 |
|
AUSWDAT5 |
Key Date for Version Selection |
QVERSDAT |
|
DATS |
|
8 |
0 |
|
DUMMY10 |
Text Line for Additional Information |
QTXT10 |
|
CHAR |
|
10 |
0 |
|
DUMMY20 |
Text Line for Additional Information |
QTXT20 |
|
CHAR |
|
20 |
0 |
|
DUMMY40 |
Text Line for Additional Information |
QTXT40 |
|
CHAR |
|
40 |
0 |
|
CHARACT_ID1 |
Characteristic Description for Quality Data Exchange |
QCHARACT_ID1 |
|
CHAR |
|
40 |
0 |
|
QERGDATH |
Planned Results Data Origin |
QERGDATHPL |
TQ73
|
CHAR |
|
2 |
0 |
|
EEANTVERF |
Fraction Calculation |
QEANTVERF |
TQ72
|
CHAR |
|
2 |
0 |
|
QDYNREGEL |
Dynamic Modification Rule |
QDYNREGEL |
QDDR
|
CHAR |
|
3 |
0 |
|
DYNMERKREF |
Characteristic (in Plan) whose Q-Level Will Be Copied |
QMERKDYN |
|
NUMC |
|
4 |
0 |
|
PZLFH |
Assigned Test Equipment |
QPZLFH |
|
NUMC |
|
8 |
0 |
|
CODEGRQUAL |
Defect Code Group for General Rejection |
QCODEGRPQL |
|
CHAR |
|
8 |
0 |
|
CODEQUAL |
Defect Code for Rejection: General |
QCODEQL |
|
CHAR |
|
4 |
0 |
|
SPCKRIT |
SPC Criterion |
QSPCKRIT |
QPSP
|
CHAR |
|
3 |
0 |
|
INPPROC |
Parameters for Input Processing in QM Results Recording |
QINPPROC |
TQ71
|
CHAR |
|
3 |
0 |
|
RES_PLAN |
Response Plan |
QP_RESPLAN |
TQPC_RESPLAN
|
CHAR |
|
3 |
0 |
|
CTRMETH |
Control Method |
QP_CTRMETH |
TQPC_CTRMETH
|
CHAR |
|
3 |
0 |
|
CHAORIG |
Inspection Characteristic Origin |
QP_CHAORIG |
TQPC_CHAORIG
|
CHAR |
|
3 |
0 |
|
CHAORIG_GUID |
Reference to Characteristic That Was Adopted |
QP_CHAORIG_GUID |
|
RAW |
|
16 |
0 |
|
NO_INSPECTION |
Do Not Copy Inspection Characteristic to Inspection Lot |
QP_NO_INSPECTION |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
QP_CHAORIG_ID |
Original Identification for Characteristic |
QMIP_CHAORIG_ID |
|
CHAR |
|
40 |
0 |
|
PLNAL |
Group Counter |
PLNAL |
|
CHAR |
|
2 |
0 |
|
PLNFL |
Sequence |
PLNFOLGE |
|
CHAR |
|
6 |
0 |
|
VORNR |
Operation/Activity Number |
VORNR |
|
CHAR |
|
4 |
0 |
|
VPLTY |
Type of the referenced task list |
VPLNTY |
|
CHAR |
|
1 |
0 |
|
VPLNR |
Group of the referenced task list |
VPLNNR |
|
CHAR |
|
8 |
0 |
|
VPLAL |
Group counter of the referenced task list |
VPLNAL |
|
CHAR |
|
2 |
0 |
|
IDENT |
Operation ID |
OPRID |
|
CHAR |
|
8 |
0 |
|
IDENT_REF |
Operation ID of the referenced operation |
OPR_REFID |
|
CHAR |
|
8 |
0 |
|
HERKUNFT |
Origin of an operation |
OPR_HER |
|
CHAR |
|
1 |
0 |
Possible values
0 |
Operation from current routing |
1 |
Operation from referenced routing |
2 |
Dummy operation |
3 |
Referenced work center operation set |
4 |
Sub-operation from current routing |
5 |
Sub-operation from referenced routing |
|
DATUB |
Valid-to date |
DATUB |
|
DATS |
|
8 |
0 |
|
AENNR_AUS |
To change number |
CPCS_ECN_TO |
|
CHAR |
|
12 |
0 |
|
QUANTITAT |
Quantitative Characteristic |
QKZQUNMK |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
MESSWERTE |
Measured Values Must Be Recorded |
QKZQUMK |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
PRUEFKAT |
Reference to Characteristic Attribute Required |
QKZPKAT |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
TOLEROBEN |
Upper Specification Limit |
QKZTOLOB |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
TOLERUNTEN |
Lower Specification Limit |
QKZTOLUN |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
SOLLPRUEF |
Check Target Value |
QKZSOLLPR |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
PUMFKZ |
Inspection Scope |
QPUMFKZ |
|
CHAR |
|
1 |
0 |
Possible values
= |
Fixed inspection scope |
NULL |
Scope not fixed |
< |
Smaller inspection scope allowed |
> |
Larger inspection scope allowed |
|
LZEITKZ |
Long-Term Inspection |
QLZEITKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
ESTUKZ |
Recording Type |
QESTUKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Summarized recording |
+ |
Single-value recording |
* |
Classed recording |
- |
No results recording |
|
DOKUKZ |
Documentation Required for Inspection Results |
QDOKUKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Text documentation of test values is not required |
. |
The test values with valuation R (reject) must be documented |
+ |
All test values must be documented with text |
|
RZWANG |
Characteristic Category |
QRZWANG |
|
CHAR |
|
1 |
0 |
Possible values
X |
Required characteristic |
NULL |
Optional characteristic |
+ |
Required when previous required characteristic is accepted |
- |
Required when previous required characteristic is rejected |
|
SYNCRO |
Synchronization is Active |
QSYNCRO |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
ADDPRO |
Sample Quantity Is Added |
QADDPRO |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
ZERSTPRF |
Destructive Inspection |
QKZDESTROY |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
FORMELMK |
Calculated Characteristic |
QKZFORMEL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
No Formula |
1 |
Input Processing |
X |
Calculated Characteristic |
|
STICHPR |
Sampling Procedure is Required |
QSTICHPR |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
AUSSLOS |
Characteristic Relevant for Qual. Score and Scrap Share |
QAUSSLOS |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
FIXIERT |
Default Control Indicators Cannot Be Changed |
QNAENDKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
BEWFHLZHL |
Recording the Number of Defects |
QBFHLZHL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
LSTKZ |
Control Characteristics Results - QM Subsystem |
QLEITSTKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
VORGAEND |
Specifications Can Be Changed |
QVORGAEND |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
PMMZWANG |
Assignment of Test Equipment Required |
QPMZWANG |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
FEHLREC |
Defects Recording Automatically Called Up |
QFEHLREC |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
AENDBELEG |
Create Change Documents During Results Recording |
QKZAENBEL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
QSPCMK |
SPC Characteristic |
QSPCMK |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
KEINDRUCK |
Print |
QDRUCK1 |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Print |
X |
Do not print |
* |
Do not print at skip |
|
PARA |
Control Indicator "Parameter Characteristic" Set/Not Set |
QPARA |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
PROCESSMK |
Process Characteristic |
QKZPROCCHAR |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
MATKZ |
Material Considered for Dynamic Modification |
QMATKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
LIEFKZ |
Vendor Considered for Dynamic Modification |
QLIFKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
HERSTKZ |
Manufacturer Considered for Dynamic Modification |
QHERSTKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
KUNDKZ |
Customer Considered for Dynamic Modification |
QKUNDKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
MASCHKZ |
Machine Considered for Dynamic Modification |
QMASCHKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
PROKZ |
Project Considered for Dynamic Modification |
QPROKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
VSTEUERKZ |
Key Containing Preset Characteristic Control Indicators |
QSTEUERKZ |
TQ27
|
CHAR |
|
4 |
0 |
|
PSNFH |
Item Number for Production Resource/Tool |
PSNFH |
|
NUMC |
|
4 |
0 |
|
FHMNR |
Production resource/tool number |
FHMNR |
|
CHAR |
|
33 |
0 |
|
KZUMFS |
Multiple Samples |
QKZUMFS |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
No multiple samples |
X |
Independent multiple samples |
1 |
Dependent multiple samples |
|
ATINN |
Internal characteristic |
ATINN |
|
NUMC |
|
10 |
0 |
|
ATNAM |
Name of the Class Characteristic |
QATNAM |
|
CHAR |
|
30 |
0 |
|
SLWBEZ |
Identification for the Inspection Point Field Combination |
QSLWBEZ |
|
CHAR |
|
3 |
0 |
|
QDYNHEAD |
Level at Which Dynamic Modification Parameters Are Defined |
QDYNHEAD |
|
CHAR |
|
1 |
0 |
|
TXTZ1 |
First line of text for production resources/tools |
TXTZ1 |
|
CHAR |
|
40 |
0 |
|
STICHPRTXT |
Short Text for the Sampling Procedure |
QTXTSMPPRO |
|
CHAR |
|
40 |
0 |
|
MASTERCTXT |
Short Text for Inspection Characteristic |
QTXT_CHA |
|
CHAR |
|
40 |
0 |
|
FLG_LOCK |
Inspection Characteristic Is Locked |
CHA_LOCK |
|
CHAR |
|
1 |
0 |
Possible values
X |
Flag set. Event has occurred. |
NULL |
Flag is Not Set |
|
HANDLE |
Internal ID of an object |
HANDLE |
|
INT4 |
|
10 |
0 |
|