- Home
- Resources
- SAP Tables
- EGERS - IS-U Device Master Data
SAP Table EGERS
IS-U Device Master Data
EGERS (IS-U Device Master Data) is a standard table in SAP R\3 ERP systems. Below you can find the technical details of the fields that make up this table. Key fields are marked in blue.
Additionally we provide an overview of foreign key relationships, if any, that link EGERS to other SAP tables.
Source: EGERS (IS-U Device Master Data)
EGERS table fields
Field |
Data element |
Checktable |
Datatype |
Length |
Decimals |
|
MANDT |
Client |
MANDT |
T000
|
CLNT |
|
3 |
0 |
|
EQUNR |
Equipment Number |
EQUNR |
EQUI
|
CHAR |
|
18 |
0 |
|
EAGRUPPE |
Input/output group |
EAGRUPPE |
|
CHAR |
|
8 |
0 |
|
KOMGRP |
ARCR Command Group |
KOMGRP |
|
CHAR |
|
8 |
0 |
|
LOS |
Sample lot |
LOS |
|
CHAR |
|
8 |
0 |
|
MESSDRCK |
Measured Pressure (Outlet Pressure) in Bars |
MESSDRCK |
|
DEC |
|
7 |
4 |
|
UEBERVER |
Transformation ratio |
UEBERVER |
|
DEC |
|
10 |
3 |
|
BESITZ |
Inspection relevance of device |
BESITZ |
|
NUMC |
|
2 |
0 |
|
BGLJAHR |
Certification Year |
BGLJAHR |
|
NUMC |
|
4 |
0 |
|
WECHSEL |
Advance replacement year |
WECHSEL |
|
NUMC |
|
4 |
0 |
|
BGLSTAT |
Certification status |
BGLSTAT |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
No restriction |
1 |
No lot allocation possible |
2 |
No certification possible at present |
3 |
Certification no longer valid |
|
KZSTICH |
Status of sample device |
KZSTICH |
|
CHAR |
|
1 |
0 |
|
SCHWGRAD |
Difficulty level: Factor for meter reader payment |
SCHWGRAD |
|
DEC |
|
3 |
1 |
|
PLOMBDAT |
Date of last lead sealing |
PLOMBDAT |
|
DATS |
|
8 |
0 |
|
BGLART |
Type of certification |
BGLART |
TE359
|
CHAR |
|
2 |
0 |
|
BGLNUM |
Certification number |
BGLNUM |
|
CHAR |
|
15 |
0 |
|
UMBAUDAT |
Modification date |
UMBAUDAT |
|
DATS |
|
8 |
0 |
|
UMBAUGR |
Modification reason |
UMBAUGR |
TE791
|
CHAR |
|
2 |
0 |
|
EICHFAEL |
Use calibration validity |
EICHFAEL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Field inactive |
X |
Field active |
|
PARAMETR |
Parametrization |
PARAMETR |
TE927
|
CHAR |
|
8 |
0 |
|
PLOMBE |
Seal code |
PLOMBE |
TE937
|
CHAR |
|
2 |
0 |
|
AEDAT |
Changed On |
AEDAT |
|
DATS |
|
8 |
0 |
|
AENAM |
Name of Person Who Changed Object |
AENAM |
|
CHAR |
|
12 |
0 |
|
ZSPANNS |
Register factor: secondary transformer voltage |
E_ZSPANNS |
|
DEC |
|
4 |
1 |
|
ZSTROMS |
Register factor: secondary transformer current |
E_ZSTROMS |
|
DEC |
|
5 |
2 |
|
ZSPANNP |
Register factor: primary transformer voltage |
E_ZSPANNP |
|
DEC |
|
6 |
0 |
|
ZSTROMP |
Register factor: primary transformer current |
E_ZSTROMP |
|
DEC |
|
5 |
1 |
|
PRGRUPPE |
Inspection point group |
PRGRUPPE |
|
CHAR |
|
8 |
0 |
|
BGLNETZ |
Certify installed devices |
BGLNETZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Field inactive |
X |
Field active |
|
ORDER_CODE |
Special Order Code for Dev./Dev. Category in Replacement |
ORDERCODE2 |
TEWOCODES
|
CHAR |
|
4 |
0 |
|
APPROVALNR |
Device inspection number |
APPROVALNR |
|
CHAR |
|
15 |
0 |
|
VLZEIT_DEV |
Individual cal. validity (years) of dev. subject to certif. |
VLZEIT_DEV |
|
DEC |
|
2 |
0 |
|
NOTIF_CODE |
Notification code |
NOTIF_CODE |
TENOCODES
|
CHAR |
|
4 |
0 |
|
EGERS foreign key relationships
Table |
Field |
Foreign key table |
Foreign key field |
Check table |
Check field |
EGERS |
BGLART |
EGERS |
MANDT |
TE359 |
Certificat. Types |
MANDT |
EGERS |
BGLART |
EGERS |
BGLART |
TE359 |
Certificat. Types |
BGLART |
EGERS |
EQUNR |
EGERS |
MANDT |
EQUI |
Equipment master data |
MANDT |
EGERS |
EQUNR |
EGERS |
EQUNR |
EQUI |
Equipment master data |
EQUNR |
EGERS |
MANDT |
EGERS |
MANDT |
T000 |
Clients |
MANDT |
EGERS |
NOTIF_CODE |
EGERS |
MANDT |
TENOCODES |
Notification Codes |
MANDT |
EGERS |
NOTIF_CODE |
EGERS |
NOTIF_CODE |
TENOCODES |
Notification Codes |
NOTIF_CODE |
EGERS |
ORDER_CODE |
EGERS |
MANDT |
TEWOCODES |
Order Codes |
MANDT |
EGERS |
ORDER_CODE |
EGERS |
ORDER_CODE |
TEWOCODES |
Order Codes |
ORDER_CODE |
EGERS |
PARAMETR |
EGERS |
MANDT |
TE927 |
Parametr. for Device |
MANDT |
EGERS |
PARAMETR |
EGERS |
PARAMETR |
TE927 |
Parametr. for Device |
PARAMETR |
EGERS |
PLOMBE |
EGERS |
MANDT |
TE937 |
Seal Code for Sample Lot |
MANDT |
EGERS |
PLOMBE |
EGERS |
PLOMBE |
TE937 |
Seal Code for Sample Lot |
PLOMBE |
EGERS |
UMBAUGR |
EGERS |
MANDT |
TE791 |
Mod.Reasons |
MANDT |
EGERS |
UMBAUGR |
EGERS |
UMBAUGR |
TE791 |
Mod.Reasons |
UMBAUGR |