PDCPT table fields
Field |
Data element |
Checktable |
Datatype |
Length |
Decimals |
|
LDATE |
Logical Date |
LDATE |
|
DATS |
|
8 |
0 |
|
BEGTM |
Start time |
CTIMB |
|
CHAR |
|
6 |
0 |
|
ENDTM |
End time |
CTIME |
|
CHAR |
|
6 |
0 |
|
BGCOD |
Attendance/absence reason for begin entry |
BGCOD |
|
CHAR |
|
4 |
0 |
|
EGCOD |
Attendance/absence reason for end entry |
EGCOD |
|
CHAR |
|
4 |
0 |
|
BTERM |
Terminal ID of start entry |
BTERM |
|
CHAR |
|
4 |
0 |
|
ETERM |
Terminal ID of end entry |
ETERM |
|
CHAR |
|
4 |
0 |
|
BSART |
Time event pair start |
BSATZA |
|
CHAR |
|
3 |
0 |
Possible values
01 |
Clock-in |
02 |
Clock-out |
03 |
Clock-in/-out |
04 |
Start of off-site work |
05 |
End of off-site work |
06 |
Start or end of off-site work |
07 |
Start of off-site work at home |
08 |
End of off-site work at home |
09 |
Start or end of off-site work at home |
A10 |
Start teardown PP |
A20 |
Partial teardown PP |
A30 |
Interrupt teardown PP |
A40 |
Finish teardown PP |
B10 |
Start processing PP |
B20 |
Partial processing PP |
B30 |
Interrupt processing PP |
B40 |
Finish processing PP |
I20 |
Time ticket PM partial confirmation |
I40 |
Time ticket PM final confirmation |
K10 |
Currently not in use |
K20 |
Currently not in use |
K30 |
Currently not in use |
L20 |
Time ticket PP partial confirmation |
L40 |
Time ticket PP final confirmation |
N10 |
PM work start |
N20 |
PM work part-finish |
N30 |
PM work interruption |
N40 |
PM work finish |
P01 |
Clock-in/-out |
P02 |
Start or end of break |
P03 |
Start or end of off-site work |
P04 |
Start or end of off-site work at home |
P05 |
Interim entry |
P10 |
Clock-in |
P11 |
Change |
P15 |
Start of break |
P20 |
Clock-out |
P25 |
End of break |
P30 |
Start of off-site work |
P35 |
Start of off-site work at home |
P40 |
End of off-site work |
P45 |
End of off-site work at home |
P50 |
External wage type |
P60 |
Information entry |
R10 |
Begin setup PP |
R20 |
Partial setup PP |
R30 |
Interrupt setup PP |
R40 |
Finish setup PP |
S10 |
Start of malfunction (not yet released) |
S40 |
End of malfunction (not yet released) |
T20 |
Time ticket PS partial confirmation |
T40 |
Time ticket PS final confirmation |
V20 |
Partial variable activity PP |
V40 |
Finish variable activity PP |
W10 |
PS work start |
W20 |
PS work part-finish |
W30 |
PS work interruption |
W40 |
PS work finish |
|
ESART |
Time event pair end |
ESATZA |
|
CHAR |
|
3 |
0 |
Possible values
01 |
Clock-in |
02 |
Clock-out |
03 |
Clock-in/-out |
04 |
Start of off-site work |
05 |
End of off-site work |
06 |
Start or end of off-site work |
07 |
Start of off-site work at home |
08 |
End of off-site work at home |
09 |
Start or end of off-site work at home |
A10 |
Start teardown PP |
A20 |
Partial teardown PP |
A30 |
Interrupt teardown PP |
A40 |
Finish teardown PP |
B10 |
Start processing PP |
B20 |
Partial processing PP |
B30 |
Interrupt processing PP |
B40 |
Finish processing PP |
I20 |
Time ticket PM partial confirmation |
I40 |
Time ticket PM final confirmation |
K10 |
Currently not in use |
K20 |
Currently not in use |
K30 |
Currently not in use |
L20 |
Time ticket PP partial confirmation |
L40 |
Time ticket PP final confirmation |
N10 |
PM work start |
N20 |
PM work part-finish |
N30 |
PM work interruption |
N40 |
PM work finish |
P01 |
Clock-in/-out |
P02 |
Start or end of break |
P03 |
Start or end of off-site work |
P04 |
Start or end of off-site work at home |
P05 |
Interim entry |
P10 |
Clock-in |
P11 |
Change |
P15 |
Start of break |
P20 |
Clock-out |
P25 |
End of break |
P30 |
Start of off-site work |
P35 |
Start of off-site work at home |
P40 |
End of off-site work |
P45 |
End of off-site work at home |
P50 |
External wage type |
P60 |
Information entry |
R10 |
Begin setup PP |
R20 |
Partial setup PP |
R30 |
Interrupt setup PP |
R40 |
Finish setup PP |
S10 |
Start of malfunction (not yet released) |
S40 |
End of malfunction (not yet released) |
T20 |
Time ticket PS partial confirmation |
T40 |
Time ticket PS final confirmation |
V20 |
Partial variable activity PP |
V40 |
Finish variable activity PP |
W10 |
PS work start |
W20 |
PS work part-finish |
W30 |
PS work interruption |
W40 |
PS work finish |
|
STAT1 |
Status from pair formation |
PCST1 |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Pair is error-free |
1 |
Only interim postings |
2 |
No clock-in |
3 |
No clock-out |
4 |
No end time for break |
5 |
No start time for break |
7 |
No start time for off-site work |
8 |
No end time for off-site work |
A |
Pair was delimited in time evaluation |
E |
Order confirmation missing |
|
STAT2 |
Status from time evaluation |
PCST2 |
|
CHAR |
|
1 |
0 |
|
COGOS |
Attendance or absence status in pair formation |
COGOS |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Start (absent before clock-in) |
0 |
On break |
1 |
At work |
3 |
Off-site |
4 |
Absent before clock-in (do not use for new pair formation) |
5 |
Absent after clock-out |
6 |
Absent before clock-in with interim postings |
7 |
Absent after clock-out with interim postings |
E |
Error |
R |
Restart after error |
|
AESTA |
Change status |
AESTA |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Both time events were entered in the time recording system |
1 |
The begin time event was entered manually |
2 |
The end time event was entered manually |
3 |
Both time events were entered manually |
|
BUSER |
Multi-purpose field for begin entry |
PDC_BUSER |
|
CHAR |
|
20 |
0 |
|
EUSER |
Multi-purpose field for end entry |
PDC_EUSER |
|
CHAR |
|
20 |
0 |
|
BPDSN |
Sequential number for PDC messages |
PDSNR_D |
|
NUMC |
|
12 |
0 |
|
EPDSN |
Sequential number for PDC messages |
PDSNR_D |
|
NUMC |
|
12 |
0 |
|
START_BEF_ZERO |
Start Before 00:00 |
PTM_START_BEF_ZERO |
|
CHAR |
|
1 |
0 |
Possible values
|