PLMK (Inspection plan characteristics) is a standard table in SAP R\3 ERP systems. Below you can find the technical details of the fields that make up this table. Key fields are marked in blue.
Additionally we provide an overview of foreign key relationships, if any, that link PLMK to other SAP tables.
| Field | Data element | Checktable | Datatype | Length | Decimals | Possible values | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
MANDT
Client
|
MANDT |
CLNT
|
3 | 0 | ||||||||
|
PLNTY
Task List Type
|
PLNTY |
CHAR
|
1 | 0 | ||||||||
|
PLNNR
Key for Task List Group
|
PLNNR |
CHAR
|
8 | 0 | ||||||||
|
PLNKN
Number of the task list node
|
PLNKN |
NUMC
|
8 | 0 | ||||||||
|
KZEINSTELL
Characteristic Type
|
QKZEINSTMK |
CHAR
|
1 | 0 | ||||||||
|
MERKNR
Inspection Characteristic Number
|
QMERKNRP |
NUMC
|
4 | 0 | ||||||||
|
ZAEHL
Internal counter
|
CIM_COUNT |
NUMC
|
8 | 0 | ||||||||
|
GUELTIGAB
Valid-From Date
|
DATUV |
DATS
|
8 | 0 | ||||||||
|
SERNV
Technical status from
|
TECHV |
CHAR
|
12 | 0 | ||||||||
|
LOEKZ
Deletion Indicator
|
LKENZ |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
PARKZ
Indicator: inactive changes
|
PARKZ |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
AENDERGNR
Change Number
|
AENNR |
CHAR
|
12 | 0 | ||||||||
|
ERSTELLER
User who created record
|
ANNAM |
CHAR
|
12 | 0 | ||||||||
|
ERSTELLDAT
Date record created on
|
ANDAT |
DATS
|
8 | 0 | ||||||||
|
AENDERER
Name of User who Most Recently Changed the Data Record
|
QAENDERER |
CHAR
|
12 | 0 | ||||||||
|
AENDERDAT
Date on Which Data Record Was Changed
|
QDATUMAEND |
DATS
|
8 | 0 | ||||||||
|
STEUERKZ
Cntrl Indicator String for Insp. Char./Master Insp. Char.
|
QMKCONTROL |
CHAR
|
30 | 0 | ||||||||
|
QMTB_WERKS
Plant for Inspection Method
|
Q_METH_PLANT | T001W |
CHAR
|
4 | 0 | |||||||
|
PMETHODE
Inspection Method
|
QPMETHODE | QMTB |
CHAR
|
8 | 0 | |||||||
|
PMTVERSION
Version Number of the Inspection Method
|
QVERSNRPM |
CHAR
|
6 | 0 | ||||||||
|
QPMK_REF
Reference to Master Insp. Characteristic in Task List
|
QKZ_REF |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
QPMK_ZAEHL
Plant for the Master Inspection Characteristic
|
QZAEHLER |
CHAR
|
4 | 0 | ||||||||
|
VERWMERKM
Master Inspection Characteristics
|
QMERKNR | QPMK |
CHAR
|
8 | 0 | |||||||
|
MKVERSION
Version Number of the Master Inspection Characteristic
|
QVERSNRMK |
CHAR
|
6 | 0 | ||||||||
|
MKVERSDAT
Key Date for Version Selection
|
QVERSDAT |
DATS
|
8 | 0 | ||||||||
|
MERKGEW
Weighting of the Characteristic
|
QMERKGEW | TQ17A |
CHAR
|
2 | 0 | |||||||
|
PROBENR
Partial Sample No. for Inspection Charac. in Task List
|
QPROBEPL |
NUMC
|
3 | 0 | ||||||||
|
PRUEFQUALI
Inspector Qualification
|
QPRQUALIF | TQ11 |
CHAR
|
5 | 0 | |||||||
|
TOLERANZSL
Tolerance Key
|
QTOLERANZ | TQ29 |
CHAR
|
4 | 0 | |||||||
|
KURZTEXT
Short Text for Inspection Characteristic
|
QTXT_CHA |
CHAR
|
40 | 0 | ||||||||
|
LTEXTKZ
Inspection Characteristic Long Text Exists
|
QLTEXTKZ |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
LTEXTSPR
Language Key
|
SPRAS |
LANG
|
1 | 0 | ||||||||
|
LTEXTEKZ
Physical-Sample-Drawing Text Exists
|
QKZPRZIEH |
CHAR
|
1 | 0 | ||||||||
|
LTXTENTSPR
Language Key
|
SPRAS |
LANG
|
1 | 0 | ||||||||
|
STELLEN
Number of Places to the Right of a Decimal Point (Accuracy)
|
QSTELLEN |
INT1
|
3 | 0 | ||||||||
|
||||||||||||
|
MASSEINHSW
Unit of Measurement, in Which Quantitative Data Is Stored
|
QMASSEH | T006 |
UNIT
|
3 | 0 | |||||||
|
SOLLWERT
Target Value for a Quantitative Characteristic
|
QSOLLWERTE |
FLTP
|
16 | 16 | ||||||||
|
SOLLWNI
Value Not Initial if Set
|
QNINITIAL |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
TOLERANZOB
Upper Specification Limit
|
QTOLOB |
FLTP
|
16 | 16 | ||||||||
|
TOLOBNI
Value Not Initial if Set
|
QNINITIAL |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
TOLERANZUN
Lower Tolerance Limit
|
QTOLUN |
FLTP
|
16 | 16 | ||||||||
|
TOLUNNI
Value Not Initial if Set
|
QNINITIAL |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
KLASANZAHL
Number of Value Classes for Inspection Results
|
QKLASSZAHL |
INT1
|
3 | 0 | ||||||||
|
KLASBREITE
Class Width
|
QKLASSBR |
FLTP
|
16 | 16 | ||||||||
|
KLASBRNI
Value Not Initial if Set
|
QNINITIAL |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
KLASMITTE
Class Midpoint
|
QKLASSMIT |
FLTP
|
16 | 16 | ||||||||
|
KLASMINI
Value Not Initial if Set
|
QNINITIAL |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
GRENZEOB1
First Upper Specification Limit
|
QGRENZOB1 |
FLTP
|
16 | 16 | ||||||||
|
GRENZOB1NI
Value Not Initial if Set
|
QNINITIAL |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
GRENZEUN1
First Lower Specification Limit
|
QGRENZUN1 |
FLTP
|
16 | 16 | ||||||||
|
GRENZUN1NI
Value Not Initial if Set
|
QNINITIAL |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
GRENZEOB2
Second Upper Specification Limit
|
QGRENZOB2 |
FLTP
|
16 | 16 | ||||||||
|
GRENZOB2NI
Value Not Initial if Set
|
QNINITIAL |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
GRENZEUN2
Second Lower Specification Limit
|
QGRENZUN2 |
FLTP
|
16 | 16 | ||||||||
|
GRENZUN2NI
Value Not Initial if Set
|
QNINITIAL |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
PLAUSIOBEN
Upper Plausibility Limit
|
QPLAUSIOB |
FLTP
|
16 | 16 | ||||||||
|
PLAUSIOBNI
Value Not Initial if Set
|
QNINITIAL |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
PLAUSIUNTE
Lower Plausibility Limit
|
QPLAUSIUN |
FLTP
|
16 | 16 | ||||||||
|
PLAUSIUNNI
Value Not Initial if Set
|
QNINITIAL |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
TOLERWEIOB
Change to Upper Specification Limit
|
QTOLWOB |
FLTP
|
16 | 16 | ||||||||
|
TOLWOBNI
Value Not Initial if Set
|
QNINITIAL |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
TOLERWEIUN
Change to Lower Specification Limit
|
QTOLWUN |
FLTP
|
16 | 16 | ||||||||
|
TOLWUNNI
Value Not Initial if Set
|
QNINITIAL |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
TOLERWAB
Date from Which the Tolerance Change Is Valid
|
QTOLWAB |
DATS
|
8 | 0 | ||||||||
|
TOLERWBIS
Date Until Which the Tolerance Change Is Valid
|
QTOLWBIS |
DATS
|
8 | 0 | ||||||||
|
STICHPRVER
Sampling Procedure in Inspection Characteristic
|
QSTICHVERF |
CHAR
|
8 | 0 | ||||||||
|
FAKPLANME
Factor for Converting MatUnitOfMeasure to SampUnitOfMeasure
|
QUMREN |
FLTP
|
16 | 16 | ||||||||
|
FAKPROBME
Factor for Converting SampUnitOfMeasure to MatUnitOfMeasure
|
QUMRENPME |
FLTP
|
16 | 16 | ||||||||
|
PROBEMGEH
Sample Unit of Measure
|
QPROBME | T006 |
UNIT
|
3 | 0 | |||||||
|
PRUEFEINH
Sample Quantity Factor for Sample(Mult. Sample Unit of Msr.)
|
QPROBEFAK |
DEC
|
5 | 2 | ||||||||
|
DYNKRIT
String for Dynamic Modification Criteria (Database Relevant)
|
QDYNSTRING |
CHAR
|
10 | 0 | ||||||||
|
FORMELSL
Check and Calculate Formula in QM
|
QFORMELSL |
CHAR
|
1 | 0 | ||||||||
|
FORMEL1
Formula Field
|
QFORMEL |
CHAR
|
60 | 0 | ||||||||
|
FORMEL2
Formula Field
|
QFORMEL |
CHAR
|
60 | 0 | ||||||||
|
CODEGR9U
Defect Code Group for Rejection at Lower Tolerance
|
QCODEGRPU |
CHAR
|
8 | 0 | ||||||||
|
CODE9U
Defect Code for Rejection at Lower Specification Limit
|
QCODEU |
CHAR
|
4 | 0 | ||||||||
|
CODEVR9U
Version Number
|
QVERSNR |
CHAR
|
6 | 0 | ||||||||
|
CODEGR9O
Defect Code Group for Rejection at Upper Tolerance
|
QCODEGRPO |
CHAR
|
8 | 0 | ||||||||
|
CODE9O
Defect Code for Rejection at Upper Specification Limit
|
QCODEO |
CHAR
|
4 | 0 | ||||||||
|
CODEVR9O
Version Number
|
QVERSNR |
CHAR
|
6 | 0 | ||||||||
|
KATAB1
Catalog Entry Is a Selected Set
|
QKTTAB |
CHAR
|
1 | 0 | ||||||||
|
KATALGART1
Catalog Type of Assigned Code Group or Selected Set
|
QKATAUSW | TQ15 |
CHAR
|
1 | 0 | |||||||
|
AUSWMENGE1
Assigned Code Group or Selected Set
|
QCGRAUSW |
CHAR
|
8 | 0 | ||||||||
|
AUSWMGWRK1
Plant of the Assigned Selected Set
|
QWERKAUSW | T001W |
CHAR
|
4 | 0 | |||||||
|
AUSWVERS1
Version Number
|
QVERSNR |
CHAR
|
6 | 0 | ||||||||
|
AUSWDAT1
Key Date for Version Selection
|
QVERSDAT |
DATS
|
8 | 0 | ||||||||
|
KATAB2
Catalog Entry Is a Selected Set
|
QKTTAB |
CHAR
|
1 | 0 | ||||||||
|
KATALGART2
Catalog Type of Assigned Code Group or Selected Set
|
QKATAUSW | TQ15 |
CHAR
|
1 | 0 | |||||||
|
AUSWMENGE2
Assigned Code Group or Selected Set
|
QCGRAUSW |
CHAR
|
8 | 0 | ||||||||
|
AUSWMGWRK2
Plant of the Assigned Selected Set
|
QWERKAUSW | T001W |
CHAR
|
4 | 0 | |||||||
|
AUSWVERS2
Version Number
|
QVERSNR |
CHAR
|
6 | 0 | ||||||||
|
AUSWDAT2
Key Date for Version Selection
|
QVERSDAT |
DATS
|
8 | 0 | ||||||||
|
KATAB3
Catalog Entry Is a Selected Set
|
QKTTAB |
CHAR
|
1 | 0 | ||||||||
|
KATALGART3
Catalog Type of Assigned Code Group or Selected Set
|
QKATAUSW | TQ15 |
CHAR
|
1 | 0 | |||||||
|
AUSWMENGE3
Assigned Code Group or Selected Set
|
QCGRAUSW |
CHAR
|
8 | 0 | ||||||||
|
AUSWMGWRK3
Plant of the Assigned Selected Set
|
QWERKAUSW | T001W |
CHAR
|
4 | 0 | |||||||
|
AUSWVERS3
Version Number
|
QVERSNR |
CHAR
|
6 | 0 | ||||||||
|
AUSWDAT3
Key Date for Version Selection
|
QVERSDAT |
DATS
|
8 | 0 | ||||||||
|
KATAB4
Catalog Entry Is a Selected Set
|
QKTTAB |
CHAR
|
1 | 0 | ||||||||
|
KATALGART4
Catalog Type of Assigned Code Group or Selected Set
|
QKATAUSW | TQ15 |
CHAR
|
1 | 0 | |||||||
|
AUSWMENGE4
Assigned Code Group or Selected Set
|
QCGRAUSW |
CHAR
|
8 | 0 | ||||||||
|
AUSWMGWRK4
Plant of the Assigned Selected Set
|
QWERKAUSW | T001W |
CHAR
|
4 | 0 | |||||||
|
AUSWVERS4
Version Number
|
QVERSNR |
CHAR
|
6 | 0 | ||||||||
|
AUSWDAT4
Key Date for Version Selection
|
QVERSDAT |
DATS
|
8 | 0 | ||||||||
|
KATAB5
Catalog Entry Is a Selected Set
|
QKTTAB |
CHAR
|
1 | 0 | ||||||||
|
KATALGART5
Catalog Type of Assigned Code Group or Selected Set
|
QKATAUSW | TQ15 |
CHAR
|
1 | 0 | |||||||
|
AUSWMENGE5
Assigned Code Group or Selected Set
|
QCGRAUSW |
CHAR
|
8 | 0 | ||||||||
|
AUSWMGWRK5
Plant of the Assigned Selected Set
|
QWERKAUSW | T001W |
CHAR
|
4 | 0 | |||||||
|
AUSWVERS5
Version Number
|
QVERSNR |
CHAR
|
6 | 0 | ||||||||
|
AUSWDAT5
Key Date for Version Selection
|
QVERSDAT |
DATS
|
8 | 0 | ||||||||
|
DUMMY10
Text Line for Additional Information
|
QTXT10 |
CHAR
|
10 | 0 | ||||||||
|
DUMMY20
Text Line for Additional Information
|
QTXT20 |
CHAR
|
20 | 0 | ||||||||
|
DUMMY40
Text Line for Additional Information
|
QTXT40 |
CHAR
|
40 | 0 | ||||||||
|
CHARACT_ID1
Characteristic Description for Quality Data Exchange
|
QCHARACT_ID1 |
CHAR
|
40 | 0 | ||||||||
|
QERGDATH
Planned Results Data Origin
|
QERGDATHPL | TQ73 |
CHAR
|
2 | 0 | |||||||
|
EEANTVERF
Fraction Calculation
|
QEANTVERF | TQ72 |
CHAR
|
2 | 0 | |||||||
|
QDYNREGEL
Dynamic Modification Rule
|
QDYNREGEL | QDDR |
CHAR
|
3 | 0 | |||||||
|
DYNMERKREF
Characteristic (in Plan) whose Q-Level Will Be Copied
|
QMERKDYN |
NUMC
|
4 | 0 | ||||||||
|
PZLFH
Assigned Test Equipment
|
QPZLFH |
NUMC
|
8 | 0 | ||||||||
|
CODEGRQUAL
Defect Code Group for General Rejection
|
QCODEGRPQL |
CHAR
|
8 | 0 | ||||||||
|
CODEQUAL
Defect Code for Rejection: General
|
QCODEQL |
CHAR
|
4 | 0 | ||||||||
|
SPCKRIT
SPC Criterion
|
QSPCKRIT | QPSP |
CHAR
|
3 | 0 | |||||||
|
INPPROC
Parameters for Input Processing in QM Results Recording
|
QINPPROC | TQ71 |
CHAR
|
3 | 0 | |||||||
|
RES_PLAN
Response Plan
|
QP_RESPLAN | TQPC_RESPLAN |
CHAR
|
3 | 0 | |||||||
|
CTRMETH
Control Method
|
QP_CTRMETH | TQPC_CTRMETH |
CHAR
|
3 | 0 | |||||||
|
CHAORIG
Inspection Characteristic Origin
|
QP_CHAORIG | TQPC_CHAORIG |
CHAR
|
3 | 0 | |||||||
|
CHAORIG_GUID
Reference to Characteristic That Was Adopted
|
QP_CHAORIG_GUID |
RAW
|
16 | 0 | ||||||||
|
NO_INSPECTION
Do Not Copy Inspection Characteristic to Inspection Lot
|
QP_NO_INSPECTION |
CHAR
|
1 | 0 | ||||||||
|
||||||||||||
|
QP_CHAORIG_ID
Original Identification for Characteristic
|
QMIP_CHAORIG_ID |
CHAR
|
40 | 0 | ||||||||
| Table | Field | Foreign key table | Foreign key field | Check table | Check field |
|---|---|---|---|---|---|
| PLMK | AUSWMGWRK1 | PLMK | MANDT |
T001W
Plants/Branches
|
MANDT |
| PLMK | AUSWMGWRK1 | PLMK | AUSWMGWRK1 |
T001W
Plants/Branches
|
WERKS |
| PLMK | AUSWMGWRK2 | PLMK | MANDT |
T001W
Plants/Branches
|
MANDT |
| PLMK | AUSWMGWRK2 | PLMK | AUSWMGWRK2 |
T001W
Plants/Branches
|
WERKS |
| PLMK | AUSWMGWRK3 | PLMK | MANDT |
T001W
Plants/Branches
|
MANDT |
| PLMK | AUSWMGWRK3 | PLMK | AUSWMGWRK3 |
T001W
Plants/Branches
|
WERKS |
| PLMK | AUSWMGWRK4 | PLMK | MANDT |
T001W
Plants/Branches
|
MANDT |
| PLMK | AUSWMGWRK4 | PLMK | AUSWMGWRK4 |
T001W
Plants/Branches
|
WERKS |
| PLMK | AUSWMGWRK5 | PLMK | MANDT |
T001W
Plants/Branches
|
MANDT |
| PLMK | AUSWMGWRK5 | PLMK | AUSWMGWRK5 |
T001W
Plants/Branches
|
WERKS |
| PLMK | CHAORIG | PLMK | MANDT |
TQPC_CHAORIG
Inspection-Characteristic Origin
|
CLIENT |
| PLMK | CHAORIG | PLMK | CHAORIG |
TQPC_CHAORIG
Inspection-Characteristic Origin
|
CHAORIG |
| PLMK | CTRMETH | PLMK | MANDT |
TQPC_CTRMETH
Control Methods
|
CLIENT |
| PLMK | CTRMETH | PLMK | CTRMETH |
TQPC_CTRMETH
Control Methods
|
CTRMETH |
| PLMK | EEANTVERF | PLMK | MANDT |
TQ72
Type of share calculation
|
MANDT |
| PLMK | EEANTVERF | PLMK | EEANTVERF |
TQ72
Type of share calculation
|
ANTVERF |
| PLMK | INPPROC | PLMK | MANDT |
TQ71
Input Processing in Results Recording QM
|
MANDT |
| PLMK | INPPROC | PLMK | INPPROC |
TQ71
Input Processing in Results Recording QM
|
INPPROC |
| PLMK | KATALGART1 | PLMK | MANDT |
TQ15
Inspection catalog type index
|
MANDT |
| PLMK | KATALGART1 | PLMK | KATALGART1 |
TQ15
Inspection catalog type index
|
KATALOGART |
| PLMK | KATALGART2 | PLMK | MANDT |
TQ15
Inspection catalog type index
|
MANDT |
| PLMK | KATALGART2 | PLMK | KATALGART2 |
TQ15
Inspection catalog type index
|
KATALOGART |
| PLMK | KATALGART3 | PLMK | MANDT |
TQ15
Inspection catalog type index
|
MANDT |
| PLMK | KATALGART3 | PLMK | KATALGART3 |
TQ15
Inspection catalog type index
|
KATALOGART |
| PLMK | KATALGART4 | PLMK | MANDT |
TQ15
Inspection catalog type index
|
MANDT |
| PLMK | KATALGART4 | PLMK | KATALGART4 |
TQ15
Inspection catalog type index
|
KATALOGART |
| PLMK | KATALGART5 | PLMK | MANDT |
TQ15
Inspection catalog type index
|
MANDT |
| PLMK | KATALGART5 | PLMK | KATALGART5 |
TQ15
Inspection catalog type index
|
KATALOGART |
| PLMK | MASSEINHSW | PLMK | MANDT |
T006
Units of Measurement
|
MANDT |
| PLMK | MASSEINHSW | PLMK | MASSEINHSW |
T006
Units of Measurement
|
MSEHI |
| PLMK | MERKGEW | PLMK | MERKGEW |
TQ17A
Characteristic weightings
|
MERKKLASSE |
| PLMK | MERKGEW | PLMK | MANDT |
TQ17A
Characteristic weightings
|
MANDT |
| PLMK | PMETHODE | PLMK | MANDT |
QMTB
Inspection method master record
|
MANDT |
| PLMK | PMETHODE | PLMK | QMTB_WERKS |
QMTB
Inspection method master record
|
WERKS |
| PLMK | PMETHODE | PLMK | PMETHODE |
QMTB
Inspection method master record
|
PMTNR |
| PLMK | PMETHODE | PLMK | PMTVERSION |
QMTB
Inspection method master record
|
VERSION |
| PLMK | PROBEMGEH | PLMK | PROBEMGEH |
T006
Units of Measurement
|
MSEHI |
| PLMK | PROBEMGEH | PLMK | MANDT |
T006
Units of Measurement
|
MANDT |
| PLMK | PRUEFQUALI | PLMK | MANDT |
TQ11
Inspector qualification
|
MANDT |
| PLMK | PRUEFQUALI | PLMK | PRUEFQUALI |
TQ11
Inspector qualification
|
PRFQL |
| PLMK | QDYNREGEL | PLMK | MANDT |
QDDR
Dynamic modification rule (header)
|
MANDT |
| PLMK | QDYNREGEL | PLMK | QDYNREGEL |
QDDR
Dynamic modification rule (header)
|
DYNREGEL |
| PLMK | QERGDATH | PLMK | MANDT |
TQ73
Origin of results data
|
MANDT |
| PLMK | QERGDATH | PLMK | QERGDATH |
TQ73
Origin of results data
|
QERGDATH |
| PLMK | QMTB_WERKS | PLMK | MANDT |
T001W
Plants/Branches
|
MANDT |
| PLMK | QMTB_WERKS | PLMK | QMTB_WERKS |
T001W
Plants/Branches
|
WERKS |
| PLMK | RES_PLAN | PLMK | MANDT |
TQPC_RESPLAN
Response Plans
|
CLIENT |
| PLMK | RES_PLAN | PLMK | RES_PLAN |
TQPC_RESPLAN
Response Plans
|
RES_PLAN |
| PLMK | SPCKRIT | PLMK | SPCKRIT |
QPSP
SPC criterion
|
SPCKRIT |
| PLMK | SPCKRIT | PLMK | MANDT |
QPSP
SPC criterion
|
MANDT |
| PLMK | TOLERANZSL | PLMK | MANDT |
TQ29
Defaults for target value and tolerances for characteristics
|
MANDT |
| PLMK | TOLERANZSL | PLMK | TOLERANZSL |
TQ29
Defaults for target value and tolerances for characteristics
|
TOLERANZSL |
| PLMK | VERWMERKM | PLMK | MANDT |
QPMK
Inspection characteristic master
|
MANDT |
| PLMK | VERWMERKM | PLMK | QPMK_ZAEHL |
QPMK
Inspection characteristic master
|
ZAEHLER |
| PLMK | VERWMERKM | PLMK | VERWMERKM |
QPMK
Inspection characteristic master
|
MKMNR |
| PLMK | VERWMERKM | PLMK | MKVERSION |
QPMK
Inspection characteristic master
|
VERSION |
| PLMK | ZZMKEINH | SYST | MANDT |
TCURC
Currency Codes
|
MANDT |
| PLMK | ZZMKEINH | PLMK | ZZMKEINH |
TCURC
Currency Codes
|
WAERS |