SATZART |
Record Types for QM Interface - Subsystems |
QEIFART |
|
CHAR |
|
3 |
0 |
Possible values
Q40 |
Inspection lot requirements |
Q41 |
Req. for insp. lot header record |
Q42 |
Char. specifications for subsystem |
Q45 |
Download inspection catalog entries |
Q48 |
Status changes in insp. lot |
Q51 |
Quantative original value record for single unit |
Q52 |
Qualitative orig. value rec. for sing. unit with char. code |
Q53 |
Qualitative orig. value rec. for sing. unit with valuation_ |
Q54 |
Quantative original value record for inspection point_ |
Q55 |
Qualitative orig. value rec. with char. code for insp. point |
Q56 |
Qualitative orig. value rec. with valuation for insp. point |
Q58 |
Cancel single unit record |
Q61 |
Quantative sample record |
Q62 |
Qualitative sample record with characteristic code |
Q63 |
Qualitative sample record with valuation |
Q64 |
Quantative sample record for inspection point |
Q65 |
Qualitative sample record with char. code for insp. point |
Q66 |
Qualitative sample rec. with valuation for insp. point |
Q68 |
Cancel sample record |
Q69 |
Close sample record |
Q71 |
Quantitative characteristic record |
Q72 |
Qualitative characteristic set with char. code |
Q73 |
Qualitative characteristic set with valuation |
Q79 |
Close character. |
Q83 |
Confirmation for inspection point |
Q84 |
Valuation for inspection point |
Q88 |
Usage Decision for Inspection Lot |
Q89 |
Inspection cancelled for inspection lot |
Q90 |
Insp.lot defects |
Q91 |
Operation defects |
Q92 |
Characteristic / sample defects |
Q95 |
Operation defects with reference to an inspection point |
Q96 |
Characteristic defects with reference to an inspection point |
|
RUECKMELNR |
Confirmation Number for Inspection Characteristic |
QRUECKNR |
|
NUMC |
|
8 |
0 |
|
ERFASSART |
Recording Type for Inspection Characteristic |
QEIFERFAS |
|
CHAR |
|
1 |
0 |
Possible values
A |
Measured values for single unit |
B |
Code for single unit |
C |
Valuation for single unit (O.K./n.O.K.) |
D |
Measured values for sample |
E |
Code for sample |
F |
Valuation of a sample |
G |
Measured value for characteristic |
H |
Code for characteristic |
I |
Valuation of a characteristic |
J |
Measured values for single unit in a sample |
K |
Code for single unit in a sample |
L |
Valuation for single unit in a sample |
M |
Measured values for single unit in an insp. pt.-based sample |
N |
Code for single unit in an inspection point-based sample |
O |
Valuation for single unit in inspection point-based sample |
P |
Measured values for sample for an inspection point |
Q |
Code for sample for an inspection point |
R |
Valuation for the sample for an inspection point |
|
KZBEWSUBSY |
Valuate Inspection Characteristic on Subsystem |
QEIFBEWSUB |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
BEWART |
Valuation Type for Characteristic for QM Subsystems |
QEIFBEWMK |
|
CHAR |
|
1 |
0 |
Possible values
A |
Attributive inspection for no. of non-conforming units |
B |
Attributive inspection for no. of defects |
C |
Variable inspection s method |
D |
Valuation by code |
E |
Manual Valuation |
F |
Inspection against tolerance limits |
G |
Valuation of characteristic using sample ratings |
H |
SPC inspection using quality control cards |
I |
Dependent multiple samples |
|
KZRZWANG |
Required Confirmation for Inspection Characteristic |
QEIFRWANG |
|
CHAR |
|
1 |
0 |
Possible values
X |
Required characteristic |
NULL |
Optional characteristic |
+ |
Required when previous required characteristic is accepted |
- |
Required when previous required characteristic is rejected |
|
STATUSV |
Specification Record Status |
QSTATUS |
|
CHAR |
|
1 |
0 |
|
STATUSR |
Results Record Status |
QBEASTATUS |
|
CHAR |
|
1 |
0 |
|
KZPRUMF |
Inspection Scope |
QPUMFKZ |
|
CHAR |
|
1 |
0 |
Possible values
= |
Fixed inspection scope |
NULL |
Scope not fixed |
< |
Smaller inspection scope allowed |
> |
Larger inspection scope allowed |
|
KZDOKU |
Documentation Required for Inspection Results |
QDOKUKZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Text documentation of test values is not required |
. |
The test values with valuation R (reject) must be documented |
+ |
All test values must be documented with text |
|
KZSERNR |
Serial Number To Be Recorded in QM Subsystem |
QEIFSERNR |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
KZTSTICHPR |
Partial Samples Possible |
QTSTICHPRO |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
No multiple samples |
X |
Independent multiple samples |
1 |
Dependent multiple samples |
|
KZRAST |
Indicator: Sampling Procedure for Inspection Points |
QKZRAST |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Without insp. points |
X |
Inspection points for production |
1 |
Inspection points for Plant Maintenance |
2 |
Inspection points for sample management |
|
RASTER |
Inspection Frequency (Only for Inspection with Insp. Points) |
QRASTER |
|
NUMC |
|
3 |
0 |
|
SOLLSTPANZ |
Number of Planned Partial Samples |
QEIFSTPANZ |
|
CHAR |
|
5 |
0 |
|
BEWARTSP |
Valuation Type for Sample for QM Subsystems |
QEIFBEWSP |
|
CHAR |
|
1 |
0 |
Possible values
A |
Attributive inspection for no. of non-conforming units |
B |
Attributive inspection for no. of defects |
C |
Variable inspection s method |
D |
Valuation by code |
E |
Manual Valuation |
F |
Inspection against tolerance limits |
G |
Valuation of characteristic using sample ratings |
H |
SPC inspection using quality control cards |
I |
Dependent multiple samples |
|
PRUEFLOS |
Inspection Lot Number |
QPLOS |
QALS
|
NUMC |
|
12 |
0 |
|
PLNFL |
Sequence |
PLNFOLGE |
|
CHAR |
|
6 |
0 |
|
VORNR |
Operation/Activity Number |
VORNR |
|
CHAR |
|
4 |
0 |
|
MERKNR |
Inspection Characteristic Number |
QMERKNRP |
|
NUMC |
|
4 |
0 |
|
QPMK_WERKS |
Plant for Master Inspection Characteristic |
QEIFPMKWRK |
|
CHAR |
|
4 |
0 |
|
VERWMERKM |
Master Inspection Characteristics |
QMERKNR |
QPMK
|
CHAR |
|
8 |
0 |
|
MKVERSION |
Version Number of the Master Inspection Characteristic |
QVERSNRMK |
|
CHAR |
|
6 |
0 |
|
QMTB_WERKS |
Plant for Inspection Method |
QEIFMTBWRK |
T001W
|
CHAR |
|
4 |
0 |
|
PMETHODE |
Inspection Method |
QPMETHODE |
QMTB
|
CHAR |
|
8 |
0 |
|
PMTVERSION |
Version Number of the Inspection Method |
QVERSNRPM |
|
CHAR |
|
6 |
0 |
|
PMTKURZTXT |
Short Text for Inspection Method |
QEIFPMTTXT |
|
CHAR |
|
40 |
0 |
|
PRUEFQUALI |
Inspector Qualification |
QPRQUALIF |
|
CHAR |
|
5 |
0 |
|
MERKGEW |
Weighting of the Characteristic |
QMERKGEW |
TQ17A
|
CHAR |
|
2 |
0 |
|
GEWKURZTXT |
Short Text for Characteristic Weighting |
QEIFGEWTXT |
|
CHAR |
|
40 |
0 |
|
KURZTEXT |
Short Text for the Inspection Characteristic |
QMKKURZTXT |
|
CHAR |
|
40 |
0 |
|
FORMEL |
Complete Formula for Linking Insp. Char. to QM Subsystems |
QEIFFORMEL |
|
CHAR |
|
120 |
0 |
|
DUMMY10 |
Text Line for Additional Information |
QTXT10 |
|
CHAR |
|
10 |
0 |
|
DUMMY20 |
Text Line for Additional Information |
QTXT20 |
|
CHAR |
|
20 |
0 |
|
DUMMY40 |
Text Line for Additional Information |
QTXT40 |
|
CHAR |
|
40 |
0 |
|
STELLEN |
Number of Decimal Places |
QEIFSTELLE |
|
NUMC |
|
2 |
0 |
|
MASSEINHSW |
Unit of Measurement for the Inspection Characteristic |
QEIFPRFMK |
T006
|
UNIT |
|
3 |
0 |
|
SOLLWERT |
Target Value for a Quantitative Characteristic |
QSOLLWERTC |
|
CHAR |
|
16 |
0 |
|
TOLERANZOB |
Upper Specification Limit |
QTOLOBC |
|
CHAR |
|
16 |
0 |
|
TOLERANZUN |
Lower Specification Limit |
QTOLUNC |
|
CHAR |
|
16 |
0 |
|
PLAUSIOBEN |
Upper Plausibility Limit |
QPLAUSIOBC |
|
CHAR |
|
16 |
0 |
|
PLAUSIUNTE |
Lower Plausibility Limit |
QPLAUSIUNC |
|
CHAR |
|
16 |
0 |
|
GRENZEOB1 |
First Upper Specification Limit |
QGRENZO1C |
|
CHAR |
|
16 |
0 |
|
GRENZEUN1 |
First Lower Specification Limit |
QGRENZU1C |
|
CHAR |
|
16 |
0 |
|
GRENZEOB2 |
Second Upper Specification Limit |
QGRENZO2C |
|
CHAR |
|
16 |
0 |
|
GRENZEUN2 |
Second Lower Specification Limit |
QGRENZU2C |
|
CHAR |
|
16 |
0 |
|
KATAB1 |
Catalog Entry Is a Selected Set |
QKTTAB |
|
CHAR |
|
1 |
0 |
|
KATALGART1 |
Catalog Type of Assigned Code Group or Selected Set |
QKATAUSW |
TQ15
|
CHAR |
|
1 |
0 |
|
AUSWMGWRK1 |
Plant of the Assigned Selected Set |
QWERKAUSW |
T001W
|
CHAR |
|
4 |
0 |
|
AUSWMENGE1 |
Assigned Code Group or Selected Set |
QCGRAUSW |
|
CHAR |
|
8 |
0 |
|
KATAB2 |
Catalog Entry Is a Selected Set |
QKTTAB |
|
CHAR |
|
1 |
0 |
|
KATALGART2 |
Catalog Type of Assigned Code Group or Selected Set |
QKATAUSW |
TQ15
|
CHAR |
|
1 |
0 |
|
AUSWMGWRK2 |
Plant of the Assigned Selected Set |
QWERKAUSW |
T001W
|
CHAR |
|
4 |
0 |
|
AUSWMENGE2 |
Assigned Code Group or Selected Set |
QCGRAUSW |
|
CHAR |
|
8 |
0 |
|
KATAB3 |
Catalog Entry Is a Selected Set |
QKTTAB |
|
CHAR |
|
1 |
0 |
|
KATALGART3 |
Catalog Type of Assigned Code Group or Selected Set |
QKATAUSW |
TQ15
|
CHAR |
|
1 |
0 |
|
AUSWMGWRK3 |
Plant of the Assigned Selected Set |
QWERKAUSW |
T001W
|
CHAR |
|
4 |
0 |
|
AUSWMENGE3 |
Assigned Code Group or Selected Set |
QCGRAUSW |
|
CHAR |
|
8 |
0 |
|
KATAB4 |
Catalog Entry Is a Selected Set |
QKTTAB |
|
CHAR |
|
1 |
0 |
|
KATALGART4 |
Catalog Type of Assigned Code Group or Selected Set |
QKATAUSW |
TQ15
|
CHAR |
|
1 |
0 |
|
AUSWMGWRK4 |
Plant of the Assigned Selected Set |
QWERKAUSW |
T001W
|
CHAR |
|
4 |
0 |
|
AUSWMENGE4 |
Assigned Code Group or Selected Set |
QCGRAUSW |
|
CHAR |
|
8 |
0 |
|
KATAB5 |
Catalog Entry Is a Selected Set |
QKTTAB |
|
CHAR |
|
1 |
0 |
|
KATALGART5 |
Catalog Type of Assigned Code Group or Selected Set |
QKATAUSW |
TQ15
|
CHAR |
|
1 |
0 |
|
AUSWMGWRK5 |
Plant of the Assigned Selected Set |
QWERKAUSW |
T001W
|
CHAR |
|
4 |
0 |
|
AUSWMENGE5 |
Assigned Code Group or Selected Set |
QCGRAUSW |
|
CHAR |
|
8 |
0 |
|
SOLLSTPUMF |
Sample Size to Be Inspected in QM Subsystem |
QEIFSTUMF |
|
NUMC |
|
7 |
0 |
|
PROBEMGEH |
Base Unit of Measure for the Inspection Lot |
QEIFMASS |
|
UNIT |
|
3 |
0 |
|
PROBMGFAK |
Sample Unit of Measurement Factor for QM Subsystem |
QEIFSTPFAK |
|
NUMC |
|
6 |
0 |
|
ANNAHMEZ |
Acceptance Number in Attrib. Insp. for QM Subsystems |
QEIFANNAMZ |
|
NUMC |
|
5 |
0 |
|
RUECKWEZ |
Rejection Number in Attributive Insp. for QM Subsystems |
QEIFRUECKZ |
|
NUMC |
|
5 |
0 |
|
KFAKTOR |
K-Factor for a Variable Inspection |
QKFAKTORC |
|
CHAR |
|
16 |
0 |
|
QRKNR |
Control Chart Number |
QQRKNR |
QASH
|
NUMC |
|
12 |
0 |
|
PHYSPROBE |
Number of the Partial Sample |
QPHYSPROBE |
|
NUMC |
|
6 |
0 |
|
KZKORRTRAN |
Correction Transfer Was Carried Out |
QEIFKORRTR |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Indicator is not set |
X |
Indicator is set |
|
ZAEHL |
Internal counter |
CIM_COUNT |
|
NUMC |
|
8 |
0 |
|
ANTVERF |
Fraction Calculation |
QEIFANVERF |
|
CHAR |
|
1 |
0 |
Possible values
A |
Binomial distribution |
B |
Poisson distribution |
C |
Normal distribution |
NULL |
Distribution not specified |
|