SAP Table QAQEE

Fields for inspection results recording

QAQEE (Fields for inspection results recording) is a standard table in SAP R\3 ERP systems. Below you can find the technical details of the fields that make up this table. Key fields are marked in blue.

Additionally we provide an overview of foreign key relationships, if any, that link QAQEE to other SAP tables.

QAQEE table fields

Field Data element Checktable Datatype Length Decimals
PLOSART Inspection Type QPLOSART CHAR 8 0
PLOSARTTXT Short Text for the Inspection Type QPLOSARTXT CHAR 40 0
PLNFL_VON Lower Limit of the Node Sequence for the Inspection Plan QPLNFL_VON CHAR 6 0
PLNFL_BIS Upper Limit of the Node Sequence for the Inspection Plan QPLNFL_BIS CHAR 6 0
PLNFL Sequence of Operations Within a Plan QPLNFOLGE CHAR 6 0
PLNKN Current Node Number from Order Counter APLZL QLFNKN NUMC 8 0
VORNR_VON Lower Limit for an Inspection Operation Interval QVORNR_VON CHAR 4 0
VORNR_BIS Upper Limit for an Inspection Operation Interval QVORNR_BIS CHAR 4 0
VORNR Operation Number QVORNR CHAR 4 0
VORKTXT Short Text QKURZTEXT CHAR 40 0
PRPLATZWRK Plant WERKS_D T001W CHAR 4 0
PRPLATZ Work Center QPRPLATZ CHAR 8 0
PRPLATZTXT Short Text QKURZTEXT CHAR 40 0
FHMNR Production resource/tool number FHMNR CHAR 33 0
FHKTX Description of the production resource/tool FHKTX CHAR 40 0
PLOSLTXTKZ Long Text for Inspection Lot QPLOSLTXT CHAR 1 0
PVOLTXTKZ Long Text for the Inspection Operation QPVOLTXT CHAR 1 0
PRBELTXTKZ Indicator: Long Text Available for Inspection Description QBELTXTKZ CHAR 1 0
MERKLTXTKZ Long-Text Indicator for the Characteristic Description QMERKTXTKZ CHAR 1 0
TABIXN Current Item in the Processing Table QTABIXN INT4 10 0
TFILLN Scope of the Processing Table QTFILLN INT4 10 0
ANTEIL Estimated Fraction of Nonconforming Units QANTEILC CHAR 16 0
ANTEILO Estimated Fraction Above the Tolerance Range QANTEILOC CHAR 16 0
ANTEILU Estimated Fraction Below the Tolerance Range QANTEILUC CHAR 16 0
MITTELWERT Arithmetic Mean of Valid Measured Values QMITTEWRTC CHAR 16 0
MITLSTANDC Arithmetic Mean or Standard Deviation of Measured Values QMITLSTANC CHAR 16 0
STDABW Standard Deviation of Valid Measured Values QSTDAWC CHAR 16 0
SPANNWEITE Range of Valid Measured Values QSPANNWEIC CHAR 16 0
VARIANZ Dispersion (Variance) of Valid Measured Values QVARIANZC CHAR 16 0
IVARIANZ Internal Dispersion of Valid Measured Values QIVARIANZC CHAR 16 0
MINWERT Minimum Value of the Valid Measured Values QMINWERTC CHAR 16 0
MAXWERT Maximum Value of the Valid Measured Values QMAXWERTC CHAR 16 0
MESSWERT Measured Value for a Sample Unit QMESSWERTC CHAR 16 0
MEDIAN Median of Valid Measured Values QMEDIAWRTC CHAR 16 0
FAKTOR Factor for Scale Conversion of Measured Values QFAKTOR CHAR 9 0
OFFSET Offset for the Scale Conversion of Measured Values QOFFSETC CHAR 16 0
OFFSETFAK Info on Offset, Factor and Presentation of Single Results QOFSETFAKT CHAR 80 0
PRUEFER Name of the Inspector QPRUEFER CHAR 12 0
PRUEFDATUV Inspection Start Date QPRUEFDATV DATS 8 0
PRUEFZEITV Starting Time of the Inspection QPRUEFZTV TIMS 6 0
PRUEFZEITB End Time of the Inspection QPRUEFZTB TIMS 6 0
PRUEFDATUB End Date of the Inspection QPRUEFDATB DATS 8 0
ANZPRO Number of New Partial Samples for the Insp. Characteristic QANZPRO INT2 5 0
ANZWERTP Number of Single Results that Are Missing QANZWERTP4 INT4 10 0
D_TEIL Text: Documentation Required for the Material QDTEIL CHAR 10 0
CODEKTXT1 Short Text for Code (Up to 40 Characters in Length) QTXT_CODE CHAR 40 0
CODEKTXT2 Short Text for Code (Up to 40 Characters in Length) QTXT_CODE CHAR 40 0
CODEKTXT3 Short Text for Code (Up to 40 Characters in Length) QTXT_CODE CHAR 40 0
CODEKTXT4 Short Text for Code (Up to 40 Characters in Length) QTXT_CODE CHAR 40 0
CODEKTXT5 Short Text for Code (Up to 40 Characters in Length) QTXT_CODE CHAR 40 0
CODELTXT1 Long Text Exists for the Code QLTEXTCODE CHAR 1 0
NULL Indicator is not set
X Indicator is set
CODELTXT2 Long Text Exists for the Code QLTEXTCODE CHAR 1 0
NULL Indicator is not set
X Indicator is set
CODELTXT3 Long Text Exists for the Code QLTEXTCODE CHAR 1 0
NULL Indicator is not set
X Indicator is set
CODELTXT4 Long Text Exists for the Code QLTEXTCODE CHAR 1 0
NULL Indicator is not set
X Indicator is set
CODELTXT5 Long Text Exists for the Code QLTEXTCODE CHAR 1 0
NULL Indicator is not set
X Indicator is set
GRUPPKTXT1 Short Text for the Code Group/Selected Set QTXT_GROUP CHAR 40 0
GRUPPKTXT2 Short Text for the Code Group/Selected Set QTXT_GROUP CHAR 40 0
GRUPPKTXT3 Short Text for the Code Group/Selected Set QTXT_GROUP CHAR 40 0
GRUPPKTXT4 Short Text for the Code Group/Selected Set QTXT_GROUP CHAR 40 0
GRUPPKTXT5 Short Text for the Code Group/Selected Set QTXT_GROUP CHAR 40 0
ATTRIBUT Attribute of the Results Record (Valid, Invalid,...) QATTRIBUT TQ77 CHAR 1 0
ATTRIBUT2 Attribute of the Results Record (Valid, Invalid,...) QATTRIBUT TQ77 CHAR 1 0
ATTRITEXT Description of Characteristic Attribute QATTTEXT CHAR 60 0
QERGDATH Origin of Results Data QERGDATH TQ73 CHAR 2 0
STUECKNR Counter for Inspection Unit Number QSTUECKNR NUMC 4 0
MESSWERTC Measured Value for a Sample Unit QMESSWERTC CHAR 16 0
ANZFEHLER Number of Defects Found QANZFEHL1 INT1 3 0
MBEWERTG Inspection Result Valuation QMBEWERTG CHAR 1 0
NULL No valuation
A Accepted
R Rejected
F Failed
SERIALNR Single-Unit Number for the Unit to Be Inspected QPRUEFLINR CHAR 18 0
SERIALNRVER Use Single Unit Number QSERIALNRVER CHAR 1 0
NULL Indicator is not set
X Indicator is set
SERRUECK Results Confirmation Exists for Unit to Be Inspected QSERRUECK CHAR 1 0
NULL Indicator is not set
X Indicator is set
MASCHINE General Information QMASCHINE CHAR 18 0
POSITION Test Position QPRPOS NUMC 4 0
VERSION1 Version Number QVERSNR CHAR 6 0
CODE1 Code QCODE CHAR 4 0
GRUPPE1 Code Group QCODEGRP CHAR 8 0
VERSION2 Version Number QVERSNR CHAR 6 0
CODE2 Code QCODE CHAR 4 0
GRUPPE2 Code Group QCODEGRP CHAR 8 0
VERSION3 Version Number QVERSNR CHAR 6 0
CODE3 Code QCODE CHAR 4 0
GRUPPE3 Code Group QCODEGRP CHAR 8 0
VERSION4 Version Number QVERSNR CHAR 6 0
CODE4 Code QCODE CHAR 4 0
GRUPPE4 Code Group QCODEGRP CHAR 8 0
VERSION5 Version Number QVERSNR CHAR 6 0
CODE5 Code QCODE CHAR 4 0
GRUPPE5 Code Group QCODEGRP CHAR 8 0
DYNPRO Screen Number QDYNPRO CHAR 4 0
MODUS Characteristic Filter (Processing Mode) for Inspection Chars QMODE TQ78 CHAR 4 0
DBEWERTG Valuation of the Characteristic for Dynamic Modification QDBEWERTG CHAR 1 0
NULL No valuation
A Accepted
R Rejected
F Failed
SOLLWERT Target Value for a Quantitative Characteristic QSOLLWERTC CHAR 16 0
TOLERANZOB Upper Specification Limit QTOLOBC CHAR 16 0
TOLERANZUN Lower Specification Limit QTOLUNC CHAR 16 0
GRENZEOB1 First Upper Specification Limit QGRENZO1C CHAR 16 0
GRENZEUN1 First Lower Specification Limit QGRENZU1C CHAR 16 0
GRENZOB2 Second Upper Specification Limit QGRENZO2C CHAR 16 0
GRENZUN2 Second Lower Specification Limit QGRENZU2C CHAR 16 0
PLAUSIOBEN Upper Plausibility Limit QPLAUSIOBC CHAR 16 0
PLAUSIUNTE Lower Plausibility Limit QPLAUSIUNC CHAR 16 0
KLASBREITE Class Width QKLASSBRC CHAR 16 0
KLASMITTE Class Midpoint QKLASMITC CHAR 16 0
MOMENT3 Third Central Moment of Valid Measured Values QMOMENT3C CHAR 16 0
MOMENT4 Fourth Central Moment of Valid Measured Values QMOMENT4C CHAR 16 0
KLASGRENZO Upper Class Limit (Not Considered) QKLSGRNZOC CHAR 16 0
KLASGRENZU Lower Class Limit (Considered) QKLSGRNZUC CHAR 16 0
MESSWERT2 Measured Value for a Sample Unit QMESSWERTC CHAR 16 0
MESSWERT3 Measured Value for a Sample Unit QMESSWERTC CHAR 16 0
ANTEIL2 Estimated Fraction of Nonconforming Units QANTEILC CHAR 16 0
MITTELWRT2 Arithmetic Mean of Valid Measured Values QMITTEWRTC CHAR 16 0
STDAW2 Standard Deviation of Valid Measured Values QSTDAWC CHAR 16 0
VARIANZ2 Dispersion (Variance) of Valid Measured Values QVARIANZC CHAR 16 0
STUECKNR1 Counter for Inspection Unit Number QSTUECKNR NUMC 4 0
AKTIVITAET Activity Type for Results Recording Transactions QEEACTYP CHAR 1 0
* Input masked
A Display
E Record
V Change
SCHLCODE Key Code QSTSCHL CHAR 4 0
MBEWERTG2 Inspection Result Valuation QMBEWERTG CHAR 1 0
NULL No valuation
A Accepted
R Rejected
F Failed
AUSWMENGE Assigned Code Group or Selected Set QCGRAUSWX CHAR 8 0
CODE Code QCODE CHAR 4 0
GRUPPE Code Group QCODEGRP CHAR 8 0
ANZWERTO Number of Measured Values Above the Tolerance Range QANZWERTO4 INT4 10 0
ANZWERTU Number of Measured Values Below the Tolerance Range QANZWERTU4 INT4 10 0
PROBENR Sample Number QPROBENR NUMC 6 0
LASTPROBE Last Sample Number QLSTPROBE NUMC 6 0
PRUEFBEMKT Short Text QKURZTEXT CHAR 40 0
PRLTEXTKZ Inspection Characteristic Long Text Exists QLTEXTKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
FEHLKLAS Defect Class QFEHLKLAS TQ17 CHAR 2 0
SELPLOS X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
SELPVO X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
SELMODUS X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
SELRUECKNR X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
NOSERIAL No External Numbering of Units to Be Inspected QKZNOSER CHAR 1 0
NULL Indicator is not set
X Indicator is set
KASERIAL External Numbering of Units to Be Inspected is Optional QKZKASER CHAR 1 0
NULL Indicator is not set
X Indicator is set
MUSERIAL External Numbering of Units to Be Inspected is required QKZMUSER CHAR 1 0
NULL Indicator is not set
X Indicator is set
EQUIPMENT Check of External Number Against Equipment QKZEQUI CHAR 1 0
NULL Indicator is not set
X Indicator is set
EINDEUTIG Check External Numbering to Ensure Uniqueness QKZEINDTG CHAR 1 0
NULL Indicator is not set
X Indicator is set
TEXT Text String with a Length of 80 Characters QCHAR80 CHAR 80 0
TEXT2 Text String with a Length of 40 Characters QCHAR40 CHAR 40 0
STATUSR Results Record Status QBEASTATUS TQ76 CHAR 1 0
EINVORG Only One Operation for the Lot Meets the Selection Criteria QEINVORG CHAR 1 0
NULL Indicator is not set
X Indicator is set
FKTCALL Transaction is Called Up as Function Module QFKTCALL CHAR 1 0
NULL Indicator is not set
X Indicator is set
ERFSICHT Recording View QERFSICHT CHAR 2 0
12 Single values and summarized results
10 Summarized results
11 Recording by units to be inspected
78 Control indicators
01 Old view: Measured values
02 Old view: Attribute codes
03 Old view: Nonconfoming units
04 Old view: Number of defects
05 Old view: Overview
30 Multiple Specification
77 Old view: Type of first characteristic
NULL Single values and summarized results (default view)
ERFSICHTSMAL Limiting Options in the Recording View QERFSICHTSMAL CHAR 1 0
NULL Indicator is not set
X Indicator is set
ISTWERT Mean Value Field QISTWERTC CHAR 16 0
EINFELD Field for Summarized Results or Single Results QEINFELD CHAR 50 0
SUMPLUS Field for Summarized Results or Single Results QEINFELD CHAR 50 0
EINFELDPRF Field for Summarized Results or Single Results QEINFELD CHAR 50 0
ANZWERTG Number of Inspected Sample Units QANZWERTG4 INT4 10 0
ANZFEHLEH Number of Nonconforming Sample Units QANZFEHEH4 INT4 10 0
ANZFEHLERM Number of Defects Found QANZFEHL4 INT4 10 0
SIPRUEFL Characteristic Overview of Unit to Be Inspected QSIPRUEFL CHAR 1 0
NULL Indicator is not set
X Indicator is set
SIEINFELD Characteristic Overview (Summarized) QSIEINFELD CHAR 1 0
NULL Indicator is not set
X Indicator is set
SISUMPLUS Characteristic Overview (Summarized Plus) QSISUMPLUS CHAR 1 0
NULL Indicator is not set
X Indicator is set
SIMESSEND Characteristic Overview of Confirmation of Measured Values QSIVARIAB CHAR 1 0
NULL Indicator is not set
X Indicator is set
SIAUSPRG Characteristic Overview for Characteristic Attributes QSIAUSPRG CHAR 1 0
NULL Indicator is not set
X Indicator is set
SIFEHLEH Characteristic Overview for Nonconforming Units QSIFEHLEH CHAR 1 0
NULL Indicator is not set
X Indicator is set
SIFEHLER Characteristic Overview of Defect Numbers QSIFEHLER CHAR 1 0
NULL Indicator is not set
X Indicator is set
SIUEBERB Characteristic Overview QSIUEBERB CHAR 1 0
NULL Indicator is not set
X Indicator is set
MERKNR Inspection Characteristic Number QMERKNRP NUMC 4 0
RUECKMELNR Confirmation Number for Inspection Characteristic QRUECKNR NUMC 8 0
RUECKNRVER Use Confirmation Number QRUECKNRVE CHAR 1 0
NULL Indicator is not set
X Indicator is set
ANNEHMEN Accept Characteristic (Partial Sample) QANNEHMEN CHAR 1 0
NULL Indicator is not set
X Indicator is set
RUECKWEIS Reject Characteristic (Partial Sample) QRUECKWEIS CHAR 1 0
NULL Indicator is not set
X Indicator is set
QMTB_WERKS Plant WERKS_D CHAR 4 0
PMETHODE Inspection Method QPMETHODE CHAR 8 0
PMTVERSION Version Number of the Inspection Method QVERSNRPM CHAR 6 0
QPMK_WERKS Plant WERKS_D CHAR 4 0
VERWMERKM Master Inspection Characteristics QMERKNR CHAR 8 0
MKVERSION Version Number of the Master Inspection Characteristic QVERSNRMK CHAR 6 0
STICHPRVER Sampling Procedure in Inspection Characteristic QSTICHVERF QDSV CHAR 8 0
PROBEMGEH Sample Unit of Measure QPROBME T006 UNIT 3 0
PRUEFEINH Sample Quantity Factor for Sample(Mult. Sample Unit of Msr.) QPROBEFAK DEC 5 2
PRUEFKZ Inspection Description Exists QPRUEFKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
KATALOGKZ Catalog Confirmations Available QKATALGKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
ANDSICHTXT Short Text for Characteristic View that is Displayed Next QANDSICHTX CHAR 30 0
KZFIRSTOP First Transaction Reached QKZFIRSTOP CHAR 1 0
NULL Indicator is not set
X Indicator is set
KZLASTOP Last Transaction Reached QKZLASTOP CHAR 1 0
NULL Indicator is not set
X Indicator is set
KZFIRSTFEA First Selected Characteristic Reached QKZFIRSFEA CHAR 1 0
NULL Indicator is not set
X Indicator is set
KZLASTFEAT Last Selected Characteristic Reached QKZLASTFEA CHAR 1 0
NULL Indicator is not set
X Indicator is set
KZFIRSTSAM First Selected Sample Reached QKZFISTSAM CHAR 1 0
NULL Indicator is not set
X Indicator is set
KZLASTSAMP Last Selected Sample Reached QKZLASTSAM CHAR 1 0
NULL Indicator is not set
X Indicator is set
KZFIRSTUNI First Unit to Be Inspected Reached QKZFISTUNI CHAR 1 0
NULL Indicator is not set
X Indicator is set
KZLASTUNIT Last Unit to Be Inspected Reached QKZLASTUNI CHAR 1 0
NULL Indicator is not set
X Indicator is set
URWBLOCK Record Individual Results in a Table QURWBLOCK CHAR 1 0
NULL Indicator is not set
X Indicator is set
QRKANZE Display Control Charts QRKANZE CHAR 1 0
NULL Indicator is not set
X Indicator is set
FKLWINAKT Possible Entry for Defect Class is Active QFKLWINAKT CHAR 1 0
NULL Indicator is not set
X Indicator is set
SERNPINST Record PM Serial Numbers QSERNPINST CHAR 1 0
NULL Indicator is not set
X Indicator is set
IDICALL X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
ONLYDEFNEW X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
QAUTH02 X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
QAUTH12 X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
QAUTH42 X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
QAUTH23 X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
QAUTH35 X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
QAUTH52 X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
QAUTH32 X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
QAUTH62 X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
STAT02 X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
STAT12 X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
STAT42 X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
STAT52 X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
STAT62 X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
INSPEXIT X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set
USERTEXT1 Short Description of a User Function Key QUSERTEXT CHAR 20 0
USERTEXT2 Short Description of a User Function Key QUSERTEXT CHAR 20 0
USERTEXT3 Short Description of a User Function Key QUSERTEXT CHAR 20 0
USERTEXT4 Short Description of a User Function Key QUSERTEXT CHAR 20 0
FRAMEVORGA Specifications for the Inspection QFRAVORGAB CHAR 40 0
FRAMEERGEB Inspection Results QFRAERGEBN CHAR 40 0
PRSTUFKTXT Short Text QKURZTEXT CHAR 40 0
ANZPROBAB Current Sample in Dependent Multiple Samples QANZPROBAB INT2 5 0
ANZPROBMA Maximum Samples for Dependent Multiple Samples QANZPROBMA INT2 5 0
GRAFIKON Start with Graphic QGRAFIKON CHAR 1 0
NULL Indicator is not set
X Indicator is set
CHARTTYPE Start with Graphic Type QCHARTTYPE CHAR 2 0
1 Run Values (Run Chart)
2 Histogram
3 Control Chart
4 Test Mode
5 Classed Histogram
NULL Run Values (Run Chart) (Default)
ERF_SOF Start Results Recording Using Automatic Selection QERF_SOF CHAR 1 0
NULL Indicator is not set
X Indicator is set
IMAGE_NAME Screen in Results Recording QIMAGE_NAME CHAR 40 0
ORIGINAL_INPUT Original Value Before Input Processing QORIGINAL_INPUT CHAR 25 0
DIFF_DEC_PLACES Different Number of Decimal Places QDIFF_DEC_PLACES INT2 5 0
INPPROC_READY Input Processing Successfully Completed QINPPROC_READY CHAR 1 0
NULL Indicator is not set
X Indicator is set
ESEL_MAN Expand Worklist Manually QESEL_MAN CHAR 1 0
NULL Indicator is not set
X Indicator is set
TEXT_OPEN Text Style of Open Items in Tree of QE51N QE_TEXT_OPEN NUMC 2 0
00 Copied from Higher-Level Object
01 Standard
02 Intensive
03 Inactive
04 Intensive, Critical
05 Negatively Highlighted
06 Positively Highlighted
07 Highlighted
98 Default and Icon
99 Default
TEXT_CLOSE Text Style of Completed Items in Tree of QE51N QE_TEXT_CLOSE NUMC 2 0
00 Copied from Higher-Level Object
01 Standard
02 Intensive
03 Inactive
04 Intensive, Critical
05 Negatively Highlighted
06 Positively Highlighted
07 Highlighted
98 Default and Icon
99 Default
MS_FLAG Indicator: Multiple Specifications Q_MS_FLG CHAR 1 0
NULL Insp. Plan/Assignment for Dependent Char. Specifications
X Inspection Plan/Assignment for Multiple Specifications
SIGNATURE_PROCESS X and Blank QKZ CHAR 1 0
NULL Indicator is not set
X Indicator is set

QAQEE foreign key relationships

Table Field Foreign key table Foreign key field Check table Check field
QAQEE ATTRIBUT QAQEE ATTRIBUT TQ77 Attributes for the Inspection Characteristic ATTRIBUT
QAQEE ATTRIBUT SY MANDT TQ77 Attributes for the Inspection Characteristic MANDT
QAQEE ATTRIBUT2 SY MANDT TQ77 Attributes for the Inspection Characteristic MANDT
QAQEE ATTRIBUT2 QAQEE ATTRIBUT2 TQ77 Attributes for the Inspection Characteristic ATTRIBUT
QAQEE FEHLKLAS QAQEE FEHLKLAS TQ17 Defect classes FEHLKLASSE
QAQEE FEHLKLAS SY MANDT TQ17 Defect classes MANDT
QAQEE MODUS SYST MANDT TQ78 Status-dependent processing table for insp. characteristics MANDT
QAQEE MODUS SYST TCODE TQ78 Status-dependent processing table for insp. characteristics TCODE
QAQEE MODUS QAQEE MODUS TQ78 Status-dependent processing table for insp. characteristics MODUS
QAQEE PROBEMGEH SY MANDT T006 Units of Measurement MANDT
QAQEE PROBEMGEH QAQEE PROBEMGEH T006 Units of Measurement MSEHI
QAQEE PRPLATZWRK SYST MANDT T001W Plants/Branches MANDT
QAQEE PRPLATZWRK QAQEE PRPLATZWRK T001W Plants/Branches WERKS
QAQEE QERGDATH SYST MANDT TQ73 Origin of results data MANDT
QAQEE QERGDATH QAQEE QERGDATH TQ73 Origin of results data QERGDATH
QAQEE STATUSR QAQEE STATUSR TQ76 Processing status of inspection characteristics STATUS
QAQEE STICHPRVER SY MANDT QDSV Sampling procedure MANDT
QAQEE STICHPRVER QAQEE STICHPRVER QDSV Sampling procedure STICHPRVER