MANDT |
Client |
MANDT |
T000
|
CLNT |
|
3 |
0 |
|
BUKRS |
Company Code |
BUKRS |
T001
|
CHAR |
|
4 |
0 |
|
SPARTE |
Division |
SPARTE |
TSPA
|
CHAR |
|
2 |
0 |
|
PROTMS |
Log automatic estimation |
PROTMS |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Field inactive |
X |
Field active |
|
EABLAEND |
Meter reading results can be changed |
EABLAEND |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Not modifiable: billing, est. cons. per weighting unit |
1 |
Not modifiable: billed |
2 |
Not modifiable: estimated consumption per weighting unit |
3 |
Change without limitation |
|
EABLBELG |
Indicator: do not print meter reading document in spool |
EABLBELG |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Field inactive |
X |
Field active |
|
E_ZUKERF |
Limitation on MR date of MR result |
E_ZUKERF |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Non restrictions on MR date of results |
1 |
Info: MR result with meter reading date after current date |
2 |
Error: meter reading date after current date |
3 |
Info: result with MR date after scheduled meter reading date |
4 |
Error: result with MR date after scheduled reading date |
|
UEFAKTOR1 |
Overestimation factor in percent |
UEFAKTOR1 |
|
DEC |
|
3 |
1 |
|
UEFAKTOR2 |
Overestimation factor in percent |
UEFAKTOR2 |
|
DEC |
|
3 |
1 |
|
KARSCHLABL |
Interval for suppression of meter readings for final MR |
KARSCHLABL |
|
NUMC |
|
3 |
0 |
|
KON_REL |
Auto. reflect device replacement in meter reading results |
DEVREPLACE |
|
CHAR |
|
1 |
0 |
|
DUMMYES |
Create dummy EABL for meter reading order creation |
DUMMYES |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Field inactive |
X |
Field active |
|
MSPRUMZ |
No automatic disconnection for move-in/out |
MSPRUMZ |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Field inactive |
X |
Field active |
|
LEISTMS |
Estimation of watt and resetting registers |
LEISTMS |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Estimate resetting and cumulative watt registers |
1 |
Do not estimate resetting and cumulative watt registers |
2 |
Estimate based on previous reading for validation |
|
KOABLVOR |
Prepare control reading |
KOABLVOR |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Field inactive |
X |
Field active |
|
PRORUECK |
Resetting for control/interim meter reading |
PRORUECK |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Resetting from resetting register independent of MR reason |
1 |
No resetting for control reading |
2 |
No resetting for interim meter reading |
3 |
No resetting for control and interim meter readings |
|
SERVICEABW |
Create service notification or order |
SERVICEABW |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Field inactive |
X |
Field active |
|
IGNESTIRESULTS |
Ignore Estimated Meter Reading Results During Extrapolation |
IGNESTIRESULTS |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Field inactive |
X |
Field active |
|
INTERVUPLPER |
MROC interval for upload of periodic results |
INTERVUPLPER |
|
NUMC |
|
3 |
0 |
|
INTFROMESTIRES |
Also Derive from Estimated MR Results |
INTFROMESTIRES |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Field inactive |
X |
Field active |
|
KAUFERSTRUHANL |
No meter reading order creation for inactive installations |
KAUFERSTRUHANL |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Field inactive |
X |
Field active |
|
PROPOSE_MOVEIN |
Display default move-in value |
PROPOSE_MOVEIN |
|
CHAR |
|
1 |
0 |
Possible values
X |
Flag set. Event has occurred. |
NULL |
Flag is Not Set |
|
INTV_PROP_MOVEIN |
Interval for determining default value for move-in |
INTV_PROP_MOVEIN |
|
NUMC |
|
3 |
0 |
|
INTV_INTERNET |
Interval for internet meter reading |
INTV_INTERNET |
|
NUMC |
|
3 |
0 |
|
TREAT_INTERNETMR |
Upload from Internet Meter Reading |
TREAT_INTERNETMR |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Copy Results as Control Meter Reading Results |
1 |
Take Into Account Existing Per. MR Order or Generate Ctrl MR |
2 |
Take Into Account Existing Periodic Order or Create New One |
3 |
Take Into Acc. Existing Per. MR Order Without Gen. Ctrl MR |
|
NOCHGE_BACKBMRES |
No change to billed reading during floating backbilling |
CHGE_BACKB_MRRES |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Field inactive |
X |
Field active |
|
NOCHGE_DPCMRES |
No Change to Billed Meter Reading for Dynamic Period Control |
CHGE_DPC_MRRES |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Field inactive |
X |
Field active |
|
INTV_DEVREPL |
Device replacement interval |
INTV_DEVREPL |
|
NUMC |
|
3 |
0 |
|
DEVREPL_DIALOG |
Device Replacement (Dialog) Automatically Taken into Account |
DEVREPLACE_DIALOG |
|
CHAR |
|
1 |
0 |
|
INTV_INTERIM |
Interval for Interim Meter Reading |
INTV_INTERIM |
|
NUMC |
|
3 |
0 |
|
TREAT_INTERIMMR |
Handling of Interim Meter Reading with Billing During Upload |
TREAT_INTERIMMR |
|
CHAR |
|
1 |
0 |
Possible values
1 |
Take Into Account Existing Per. MR Order or Generate Ctrl MR |
2 |
Take Into Account Existing Periodic Order or Create New One |
3 |
Take Into Acc. Existing Per. MR Order Without Gen. Ctrl MR |
|
AMI_DER_INTERVAL |
Interval for Derivation During AMI Entry |
E_AMI_MR_DERINTERVAL |
|
NUMC |
|
3 |
0 |
|
QDPLCHECK |
Validation for Final Quantity |
E_QDPLCHECK |
|
CHAR |
|
1 |
0 |
Possible values
NULL |
Validation Based on Previous Quantity |
X |
Validation Based on Final Quantity |
|