BAPI1191_CHA_C (Inspection Characteristics in CREATE-BAPI for Insp. Plans) is a standard table in SAP R\3 ERP systems. Below you can find the technical details of the fields that make up this table. Key fields are marked in blue.
Additionally we provide an overview of foreign key relationships, if any, that link BAPI1191_CHA_C to other SAP tables.
| Field | Data element | Checktable | Datatype | Length | Decimals | Possible values | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
TASK_LIST_GROUP
Key for Task List Group
|
PLNNR |
CHAR
|
8 | 0 | ||||||||||||
|
GROUP_COUNTER
Group Counter
|
PLNAL |
CHAR
|
2 | 0 | ||||||||||||
|
OPERATION_ID
Operation ID
|
OPRID |
CHAR
|
8 | 0 | ||||||||||||
|
ACTIVITY
Operation/Activity Number
|
VORNR |
CHAR
|
4 | 0 | ||||||||||||
|
INSPCHAR
Inspection Characteristic Number
|
QMERKNRP |
NUMC
|
4 | 0 | ||||||||||||
|
VALID_FROM
Valid-From Date
|
DATUV |
DATS
|
8 | 0 | ||||||||||||
|
CHANGE_NO
Change Number
|
AENNR |
CHAR
|
12 | 0 | ||||||||||||
|
CHANGE_NO_TO
To change number
|
CPCS_ECN_TO |
CHAR
|
12 | 0 | ||||||||||||
|
VALID_TO_DATE
Valid-to date
|
DATUB |
DATS
|
8 | 0 | ||||||||||||
|
DEL_IND
Deletion Indicator
|
LKENZ |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
QUANTITATIVE_IND
Quantitative Characteristic
|
QKZQUNMK |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
PRESET_CTRL_INDS_KEY
Key Containing Preset Characteristic Control Indicators
|
QSTEUERKZ |
CHAR
|
4 | 0 | ||||||||||||
|
MSTR_CHAR
Master Inspection Characteristics
|
QMERKNR |
CHAR
|
8 | 0 | ||||||||||||
|
PMSTR_CHAR
Plant
|
WERKS_D |
CHAR
|
4 | 0 | ||||||||||||
|
CHA_MASTER_IMPORT_MODUS
Mode for Reference to Master Inspection Characteristic
|
QPMK_IMPORT_MODUS |
CHAR
|
1 | 0 | ||||||||||||
|
CHAR_DESCR
Short Text for Inspection Characteristic
|
QTXT_CHA |
CHAR
|
40 | 0 | ||||||||||||
|
METHOD
Inspection Method
|
QPMETHODE |
CHAR
|
8 | 0 | ||||||||||||
|
PMETHOD
Plant for Inspection Method
|
Q_METH_PLANT |
CHAR
|
4 | 0 | ||||||||||||
|
TOLERANCE_KEY
Tolerance Key
|
QTOLERANZ |
CHAR
|
4 | 0 | ||||||||||||
|
MEAS_VALUE_CONFIRM_IND
Measured Values Must Be Recorded
|
QKZQUMK |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
ATTRIBUTE_REQUIRED_IND
Reference to Characteristic Attribute Required
|
QKZPKAT |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
UP_TOL_LMT_IND
Upper Specification Limit
|
QKZTOLOB |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
LW_TOL_LMT_IND
Lower Specification Limit
|
QKZTOLUN |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
TARGET_VAL_CHECK_IND
Check Target Value
|
QKZSOLLPR |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
SCOPE_IND
Inspection Scope
|
QPUMFKZ |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
LONG_TERM_INSP_IND
Long-Term Inspection
|
QLZEITKZ |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
RESULT_RECORDING_TYPE
Recording Type
|
QESTUKZ |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
DOCU_REQU
Documentation Required for Inspection Results
|
QDOKUKZ |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
CONFIRMATION_CATEGORY
Characteristic Category
|
QRZWANG |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
ADD_SAMPLE_QUANTITY
Sample Quantity Is Added
|
QADDPRO |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
DESTRUCTIVE_INSP_IND
Destructive Inspection
|
QKZDESTROY |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
FORMULA_IND
Calculated Characteristic
|
QKZFORMEL |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
SAMPLING_PROCEDURE_IND
Sampling Procedure is Required
|
QSTICHPR |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
QSCORE_AND_SHARE_RELEVANT
Characteristic Relevant for Qual. Score and Scrap Share
|
QAUSSLOS |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
DEFECT_NO_CONFIRMATION
Recording the Number of Defects
|
QBFHLZHL |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
INSP_TOOL_IND
Assignment of Test Equipment Required
|
QPMZWANG |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
AUTO_DEFCT_RECORDING
Defects Recording Automatically Called Up
|
QFEHLREC |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
CHANGE_DOCUMENTS_REQ
Create Change Documents During Results Recording
|
QKZAENBEL |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
SPC_IND
SPC Characteristic
|
QSPCMK |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
PRINT_IND
Print
|
QDRUCK1 |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
CH_WGT_COD
Weighting of the Characteristic
|
QMERKGEW |
CHAR
|
2 | 0 | ||||||||||||
|
PHYS_SMPL
Partial Sample No. for Inspection Charac. in Task List
|
QPROBEPL |
NUMC
|
3 | 0 | ||||||||||||
|
INSPECTOR_QUALIF
Inspector Qualification
|
QPRQUALIF |
CHAR
|
5 | 0 | ||||||||||||
|
INFOFIELD1
Text Line for Additional Information
|
QTXT10 |
CHAR
|
10 | 0 | ||||||||||||
|
INFOFIELD2
Text Line for Additional Information
|
QTXT20 |
CHAR
|
20 | 0 | ||||||||||||
|
INFOFIELD3
Text Line for Additional Information
|
QTXT40 |
CHAR
|
40 | 0 | ||||||||||||
|
CHARACTERISTIC_NAME
Characteristic Description for Quality Data Exchange
|
QCHARACT_ID1 |
CHAR
|
40 | 0 | ||||||||||||
|
RES_ORG
Planned Results Data Origin
|
QERGDATHPL |
CHAR
|
2 | 0 | ||||||||||||
|
SHARE_CALC
Fraction Calculation
|
QEANTVERF |
CHAR
|
2 | 0 | ||||||||||||
|
ITEM_NO_OF_PRODUCTION_RESOURCE
Item Number for Production Resource/Tool
|
PSNFH |
NUMC
|
4 | 0 | ||||||||||||
|
DEC_PLACES
Number of Places to the Right of a Decimal Point (Accuracy)
|
QSTELLEN |
INT1
|
3 | 0 | ||||||||||||
|
||||||||||||||||
|
MEAS_UNIT
Measurement Unit in Which Quantitative Data Is Maintained
|
QMGEH6 |
CHAR
|
6 | 0 | ||||||||||||
|
MEAS_UNIT_ISO
ISO code for unit of measurement
|
ISOCD_UNIT |
CHAR
|
3 | 0 | ||||||||||||
|
TARGET_VAL
Target Value for a Quantitative Characteristic
|
QSOLLWERTC |
CHAR
|
16 | 0 | ||||||||||||
|
UP_TOL_LMT
Upper Specification Limit
|
QTOLOBC |
CHAR
|
16 | 0 | ||||||||||||
|
LW_TOL_LMT
Lower Specification Limit
|
QTOLUNC |
CHAR
|
16 | 0 | ||||||||||||
|
NO_OF_VALUE_CLASSES
Number of Value Classes for Inspection Results
|
QKLASSZAHL |
INT1
|
3 | 0 | ||||||||||||
|
CLASS_WIDTH
Class Width
|
QKLASSBRC |
CHAR
|
16 | 0 | ||||||||||||
|
CLASS_MIDPOINT
Class Midpoint
|
QKLASMITC |
CHAR
|
16 | 0 | ||||||||||||
|
UP_LMT_1
First Upper Specification Limit
|
QGRENZO1C |
CHAR
|
16 | 0 | ||||||||||||
|
LW_LMT_1
First Lower Specification Limit
|
QGRENZU1C |
CHAR
|
16 | 0 | ||||||||||||
|
UP_LMT_2
Second Upper Specification Limit
|
QGRENZO2C |
CHAR
|
16 | 0 | ||||||||||||
|
LW_LMT_2
Second Lower Specification Limit
|
QGRENZU2C |
CHAR
|
16 | 0 | ||||||||||||
|
UP_PLS_LMT
Upper Plausibility Limit
|
QPLAUSIOBC |
CHAR
|
16 | 0 | ||||||||||||
|
LW_PLS_LMT
Lower Plausibility Limit
|
QPLAUSIUNC |
CHAR
|
16 | 0 | ||||||||||||
|
FORMULA_CHECK_BY_SAP
Check and Calculate Formula in QM
|
QFORMELSL |
CHAR
|
1 | 0 | ||||||||||||
|
FORMULA_FIELD_1
Formula Field
|
QFORMEL |
CHAR
|
60 | 0 | ||||||||||||
|
FORMULA_FIELD_2
Formula Field
|
QFORMEL |
CHAR
|
60 | 0 | ||||||||||||
|
SEL_SET1
Assigned Code Group or Selected Set
|
QCGRAUSW |
CHAR
|
8 | 0 | ||||||||||||
|
PSEL_SET1
Plant of the Assigned Selected Set
|
QWERKAUSW |
CHAR
|
4 | 0 | ||||||||||||
|
CAT_TYPE2
Catalog Type of Assigned Code Group or Selected Set
|
QKATAUSW |
CHAR
|
1 | 0 | ||||||||||||
|
CODE_GROUP2
Assigned Code Group
|
QCODEGR |
CHAR
|
8 | 0 | ||||||||||||
|
CAT_TYPE3
Catalog Type of Assigned Code Group or Selected Set
|
QKATAUSW |
CHAR
|
1 | 0 | ||||||||||||
|
CODE_GROUP3
Assigned Code Group
|
QCODEGR |
CHAR
|
8 | 0 | ||||||||||||
|
CAT_TYPE4
Catalog Type of Assigned Code Group or Selected Set
|
QKATAUSW |
CHAR
|
1 | 0 | ||||||||||||
|
CODE_GROUP4
Assigned Code Group
|
QCODEGR |
CHAR
|
8 | 0 | ||||||||||||
|
CAT_TYPE5
Catalog Type of Assigned Code Group or Selected Set
|
QKATAUSW |
CHAR
|
1 | 0 | ||||||||||||
|
CODE_GROUP5
Assigned Code Group
|
QCODEGR |
CHAR
|
8 | 0 | ||||||||||||
|
DEF_CODE_GRP_GENERAL
Defect Code Group for General Rejection
|
QCODEGRPQL |
CHAR
|
8 | 0 | ||||||||||||
|
DEF_CODE_GENERAL
Defect Code for Rejection: General
|
QCODEQL |
CHAR
|
4 | 0 | ||||||||||||
|
LW_DEF_CODE_GRP
Defect Code Group for Rejection at Lower Tolerance
|
QCODEGRPU |
CHAR
|
8 | 0 | ||||||||||||
|
LW_DEF_CODE
Defect Code for Rejection at Lower Specification Limit
|
QCODEU |
CHAR
|
4 | 0 | ||||||||||||
|
UP_DEF_CODE_GRP
Defect Code Group for Rejection at Upper Tolerance
|
QCODEGRPO |
CHAR
|
8 | 0 | ||||||||||||
|
UP_DEF_CODE
Defect Code for Rejection at Upper Specification Limit
|
QCODEO |
CHAR
|
4 | 0 | ||||||||||||
|
SMPL_PROCEDURE
Sampling Procedure in Inspection Characteristic
|
QSTICHVERF |
CHAR
|
8 | 0 | ||||||||||||
|
SMPL_UNIT
Sample Unit of Measure
|
QPROBME |
UNIT
|
3 | 0 | ||||||||||||
|
SMPL_UNIT_ISO
ISO code for unit of measurement
|
ISOCD_UNIT |
CHAR
|
3 | 0 | ||||||||||||
|
SMPL_QUANT
Sample Quantity Factor for Sample(Mult. Sample Unit of Msr.)
|
QPROBEFAK |
DEC
|
5 | 2 | ||||||||||||
|
SPC_CRITERION_KEY
SPC Criterion
|
QSPCKRIT |
CHAR
|
3 | 0 | ||||||||||||
|
DYN_MODIF_RULE
Dynamic Modification Rule
|
QDYNREGEL |
CHAR
|
3 | 0 | ||||||||||||
|
DYN_MODIF_REF_CHA
Characteristic (in Plan) whose Q-Level Will Be Copied
|
QMERKDYN |
NUMC
|
4 | 0 | ||||||||||||
|
DYN_MODIF_BY_VENDOR
Vendor Considered for Dynamic Modification
|
QLIFKZ |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
DYN_MODIF_BY_MANUFAC
Manufacturer Considered for Dynamic Modification
|
QHERSTKZ |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
DYN_MODIF_BY_CUSTOMR
Customer Considered for Dynamic Modification
|
QKUNDKZ |
CHAR
|
1 | 0 | ||||||||||||
|
||||||||||||||||
|
INPPROC
Parameters for Input Processing in QM Results Recording
|
QINPPROC |
CHAR
|
3 | 0 | ||||||||||||