RMXMS_PLKO (RMXM-TRF: Master Recipe Header) is a standard table in SAP R\3 ERP systems. Below you can find the technical details of the fields that make up this table. Key fields are marked in blue.
Additionally we provide an overview of foreign key relationships, if any, that link RMXMS_PLKO to other SAP tables.
| Field | Data element | Checktable | Datatype | Length | Decimals | Possible values | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
PLKO_KEY
|
RMXMS_PLKO_KEY |
STRU
|
0 | 0 | ||||||||||||||||||
|
MANDT
Client
|
MANDT |
CLNT
|
3 | 0 | ||||||||||||||||||
|
PLNTY
Task List Type
|
PLNTY |
CHAR
|
1 | 0 | ||||||||||||||||||
|
PLNNR
Key for Task List Group
|
PLNNR |
CHAR
|
8 | 0 | ||||||||||||||||||
|
PLNAL
Group Counter
|
PLNAL |
CHAR
|
2 | 0 | ||||||||||||||||||
|
ZAEHL
Internal counter
|
CIM_COUNT |
NUMC
|
8 | 0 | ||||||||||||||||||
|
PLKO_GR
|
RMXMS_PLKO_GR |
STRU
|
0 | 0 | ||||||||||||||||||
|
PLNME
Task list unit of measure
|
PLNME |
UNIT
|
3 | 0 | ||||||||||||||||||
|
LOSVN
From Lot Size
|
LOSGRVON |
QUAN
|
13 | 3 | ||||||||||||||||||
|
LOSBS
To lot size
|
LOSGRBIS |
QUAN
|
13 | 3 | ||||||||||||||||||
|
MEINH
Unit of Measure for Activity/Operation
|
VORME |
UNIT
|
3 | 0 | ||||||||||||||||||
|
BMSCH
Base Quantity
|
BMSCH |
QUAN
|
13 | 3 | ||||||||||||||||||
|
KTEXT
Task list description
|
PLANTEXT |
CHAR
|
40 | 0 | ||||||||||||||||||
|
TXTSP
Language Key
|
SPRAS |
LANG
|
1 | 0 | ||||||||||||||||||
|
PLKO_MR
|
RMXMS_PLKO_MR |
STRU
|
0 | 0 | ||||||||||||||||||
|
DATUV
Valid-From Date
|
DATUV |
DATS
|
8 | 0 | ||||||||||||||||||
|
TECHV
Technical status from
|
TECHV |
CHAR
|
12 | 0 | ||||||||||||||||||
|
AENNR
Change Number
|
AENNR |
CHAR
|
12 | 0 | ||||||||||||||||||
|
LOEKZ
Deletion Indicator
|
LKENZ |
CHAR
|
1 | 0 | ||||||||||||||||||
|
||||||||||||||||||||||
|
PARKZ
Indicator: inactive changes
|
PARKZ |
CHAR
|
1 | 0 | ||||||||||||||||||
|
||||||||||||||||||||||
|
ANDAT
Date record created on
|
ANDAT |
DATS
|
8 | 0 | ||||||||||||||||||
|
ANNAM
User who created record
|
ANNAM |
CHAR
|
12 | 0 | ||||||||||||||||||
|
AEDAT
Changed On
|
AEDAT |
DATS
|
8 | 0 | ||||||||||||||||||
|
AENAM
Name of Person Who Changed Object
|
AENAM |
CHAR
|
12 | 0 | ||||||||||||||||||
|
VERWE
Task list usage
|
PLN_VERWE |
CHAR
|
3 | 0 | ||||||||||||||||||
|
WERKS
Plant
|
WERKS_D |
CHAR
|
4 | 0 | ||||||||||||||||||
|
STATU
Status
|
PLNST |
CHAR
|
3 | 0 | ||||||||||||||||||
|
VAGRP
Responsible planner group/department
|
VAGRP |
CHAR
|
3 | 0 | ||||||||||||||||||
|
AESZN
Document change number (without document management system)
|
AESZN |
CHAR
|
6 | 0 | ||||||||||||||||||
|
ABDAT
Date of the last call
|
ABRUFDAT |
DATS
|
8 | 0 | ||||||||||||||||||
|
ABANZ
Number of calls
|
ABRUFANZ |
DEC
|
4 | 0 | ||||||||||||||||||
|
PROFIDNETZ
Profile
|
PROFID_STD |
CHAR
|
7 | 0 | ||||||||||||||||||
|
KOKRS
Controlling Area
|
KOKRS |
CHAR
|
4 | 0 | ||||||||||||||||||
|
QVEWERKS
Plant of Selected Set for Automatic Usage Decision
|
QVEWERKS |
CHAR
|
4 | 0 | ||||||||||||||||||
|
QVEMENGE
Selected Set for Usage Decision
|
QVEMENGE |
CHAR
|
8 | 0 | ||||||||||||||||||
|
QVEVERSION
Code Version Used for an Automatic Usage Decision
|
QVEVERSION |
CHAR
|
6 | 0 | ||||||||||||||||||
|
QVEDATUM
Date of Code Used for Usage Decision
|
QVEDATUM |
DATS
|
8 | 0 | ||||||||||||||||||
|
QVEGRUPPE
Code Group for Automatic Usage Decision
|
QVEGRUPPE |
CHAR
|
8 | 0 | ||||||||||||||||||
|
QVECODE
Code for Automatic Usage Decision
|
QVECODE |
CHAR
|
4 | 0 | ||||||||||||||||||
|
QDYNREGEL
Dynamic Modification Rule
|
QDYNREGEL |
CHAR
|
3 | 0 | ||||||||||||||||||
|
QDYNHEAD
Level at Which Dynamic Modification Parameters Are Defined
|
QDYNHEAD |
CHAR
|
1 | 0 | ||||||||||||||||||
|
QPRZIEHVER
Sample-Drawing Procedure
|
QPRZIEHVER |
CHAR
|
8 | 0 | ||||||||||||||||||
|
QVERSNPRZV
Version No. of the Sample-Drawing Procedure
|
QVERSNPRZV |
CHAR
|
6 | 0 | ||||||||||||||||||
|
QKZRASTER
Inspection Point
|
QKZRASTER |
CHAR
|
1 | 0 | ||||||||||||||||||
|
||||||||||||||||||||||
|
QDYNSTRING
String for Dynamic Modification Criteria (Database Relevant)
|
QDYNSTRING |
CHAR
|
10 | 0 | ||||||||||||||||||
|
STRAT
Maintenance strategy
|
STRAT |
CHAR
|
6 | 0 | ||||||||||||||||||
|
PPOOL
Maintenance package pool
|
PPOOL |
CHAR
|
6 | 0 | ||||||||||||||||||
|
ISTRU
Assembly
|
ISTRU |
CHAR
|
18 | 0 | ||||||||||||||||||
|
IWERK
Maintenance Planning Plant
|
IWERK |
CHAR
|
4 | 0 | ||||||||||||||||||
|
ANLZU
Syst.Condition
|
ANLZU |
CHAR
|
1 | 0 | ||||||||||||||||||
|
ARBID
Work center group with planning function
|
IGEWERK |
NUMC
|
8 | 0 | ||||||||||||||||||
|
EXTNUM
External Numbering of Units to be Inspected
|
QEXTNUM |
CHAR
|
1 | 0 | ||||||||||||||||||
|
DELKZ
Indicator: Delete completely in reorganization run
|
CP_DELKZ |
CHAR
|
1 | 0 | ||||||||||||||||||
|
||||||||||||||||||||||
|
ARBTY
Object types of the CIM resource
|
CR_OBJTY |
CHAR
|
2 | 0 | ||||||||||||||||||
|
||||||||||||||||||||||
|
STUPR
Setup recipe
|
STUPR |
CHAR
|
8 | 0 | ||||||||||||||||||
|
CLNDR
Clean-out recipe
|
CLNDR |
CHAR
|
8 | 0 | ||||||||||||||||||
|
PRTYP
Process type
|
C2_PRTYP |
NUMC
|
1 | 0 | ||||||||||||||||||
|
||||||||||||||||||||||
|
REODAT
Archive date
|
REODAT |
DATS
|
8 | 0 | ||||||||||||||||||
|
NETID
Object ID of the resource
|
CR_OBJID |
NUMC
|
8 | 0 | ||||||||||||||||||
|
FLG_CHK
Ind: Task list was submitted for consistency check
|
FLG_CHKED |
CHAR
|
1 | 0 | ||||||||||||||||||
|
||||||||||||||||||||||
|
PSPNR
Standard WBS element
|
PS_SPS_ELE |
NUMC
|
8 | 0 | ||||||||||||||||||
|
TTRAS
Task lists: Internal representation of the period pattern
|
CP_TTRAS |
NUMC
|
6 | 0 | ||||||||||||||||||
|
KZKFG
Ind: Configurable object
|
CP_KZKFG |
CHAR
|
1 | 0 | ||||||||||||||||||
|
||||||||||||||||||||||
|
PLNNR_ALT
Old number
|
CP_PLNNR_A |
CHAR
|
20 | 0 | ||||||||||||||||||
|
FLG_CAPO
Recalculate standard values at order creation using CAPP
|
FLG_CAPO |
CHAR
|
1 | 0 | ||||||||||||||||||
|
||||||||||||||||||||||
|
STLTY
BOM category
|
STLTY |
CHAR
|
1 | 0 | ||||||||||||||||||
|
||||||||||||||||||||||
|
STLNR
Bill of material
|
STNUM |
CHAR
|
8 | 0 | ||||||||||||||||||
|
STLAL
Alternative BOM
|
STLAL |
CHAR
|
2 | 0 | ||||||||||||||||||
|
SLWBEZ
Identification for the Inspection Point Field Combination
|
QSLWBEZ |
CHAR
|
3 | 0 | ||||||||||||||||||
|
PPKZTLZU
Partial Lot Assignment in an Inspection During Production
|
QPPKZTLZU |
CHAR
|
1 | 0 | ||||||||||||||||||
|
||||||||||||||||||||||
|
CHRULE
Change rule
|
R_CHRULE |
CHAR
|
1 | 0 | ||||||||||||||||||
|
||||||||||||||||||||||
|
CCOAA
Change Type for Object
|
CCOAA |
NUMC
|
3 | 0 | ||||||||||||||||||
|
ST_ARBID
Object ID
|
OBJEKTID |
NUMC
|
8 | 0 | ||||||||||||||||||
|
UMREZ
Numerator for converting task list and oper. un. of measure
|
CP_UMREZ |
DEC
|
5 | 0 | ||||||||||||||||||
|
UMREN
Denominator for converting rtg and op units of measure
|
CP_UMREN |
DEC
|
5 | 0 | ||||||||||||||||||
|
FLG_SEL
Version is valid on key date entered
|
FLGSEL |
CHAR
|
1 | 0 | ||||||||||||||||||
|
||||||||||||||||||||||
|
FLG_INV
Indicator: Not to be displayed on screen (invisible)
|
FLG_INV |
CHAR
|
1 | 0 | ||||||||||||||||||
|
VBKZ
Update indicator
|
VBKZ |
CHAR
|
1 | 0 | ||||||||||||||||||
|
||||||||||||||||||||||
|
DATUB
Valid-to date
|
DATUB |
DATS
|
8 | 0 | ||||||||||||||||||
|
AENNR_AUS
Change Number
|
AENNR |
CHAR
|
12 | 0 | ||||||||||||||||||